INSTALLATION
Additional Venting Instructions
Caution: Optimum safety, combustion and
burn quality cannot be achieved if these
guidelines are not followed. Failure to follow
these guidelines will void your warranty.
Caution: All chimney connectors must be kept
clean and in good condition.
Caution: Do not use make-shift methods or
compromises in the installation.
•
Follow all manufacturers’ ventilation
installation instructions.
•
Only use ventilation components designed and
approved for use with a pellet stove.
•
Although not recommended, straight out
horizontal venting is acceptable under certain
configurations. However if a vertical
termination is employed, minimum vertical rise
(to termination point) must be no less than the
total height of the stove.
•
Each 90° angle or T-connector adds an effect
of five additional feet of pipe length. Each
45° angle adds an effect of three additional
feet of pipe length.
•
4” venting is required in all installations at or
above elevations of 2500 feet.
•
4” venting is required in all installations where
the total length of venting is equal to or greater
than 20 feet including the effective length of
any angles.
•
A chimney connector shall not pass through
an attic or roof space, closet or similar
concealed spaces, or a floor, or ceiling.
•
The maximum length of any venting
configuration should not exceed 30 feet total,
including the effective lengths of any angles.
For US installations, this stove insert may be
installed into a masonry fireplace (built to UBC 37
or ULC S628 standards) or a factory-built fireplace
(built to UL 127 or ULC S610 standards).
When installing into a masonry chimney, it is
recommended that the exhaust vent be extended
to the top of the chimney. However, if the vent
pipe does not extend to the top of the chimney,
the vent must extend a minimum of 18” above the
damper. You must seal the damper area so that
the air / exhaust in the chimney cannot mix with
the air in the combustion chamber.
Содержание INTEGRA II
Страница 1: ...Copyright 2008 by Lucky Distributing Revision 2 0 updated 11 05 2008 1...
Страница 32: ...Copyright 2008 by Lucky Distributing Revision 2 0 updated 11 05 2008 32 CONTROL FLOW CHART...
Страница 36: ...Copyright 2008 by Lucky Distributing Revision 2 0 updated 11 05 2008 36...
Страница 37: ...Copyright 2008 by Lucky Distributing Revision 2 0 updated 11 05 2008 37...