background image

 
 
 

 

C&J DGT5000 

Suite ‘Shelf’ or ‘Slab’ Burner 

 

Owner's Book 

(THIS APPLIANCE IS FITTED WITH ALKALINE BATTERIES) 

 

INCLUDES USER, INSTALLATION & MAINTENANCE 

INSTRUCTIONS

 

 
 
 
 

Please read these instructions carefully before you start using the 

appliance 

 
 

Keep this booklet handy for future reference 

 
 

This appliance is 

for use in GREAT BRITAI or IRELAD only 

 

A QUALITY PRODUCT FROM C&J FIRES

 

 
 

Содержание DGT 5000

Страница 1: ...LKALINE BATTERIES INCLUDES USER INSTALLATION MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This ap...

Страница 2: ...ce opening dimensions 14 Hole in the Wall installations 14 Clearance to Shelf 15 Clearance to Side of Fire 15 Ventilation 15 SECTION NINE To Install the Appliance 16 Examine Flue Chimney 16 Preparing...

Страница 3: ...To keep dust to a minimum these materials should be securely wrapped in polythene and be clearly labelled RCF waste These materials are not classified as hazardous waste and should be disposed of at a...

Страница 4: ...rging if rechargeable batteries have been used Important Batteries should be changed or recharged as soon as possible as the appliance will not light if the battery power gets to low The appliance inc...

Страница 5: ...Before cleaning ensure that the appliance is turned off and cold In some instances you may experience ignition problems even when the appliance is new This may be due to the aeration hole in the pilo...

Страница 6: ...liance will automatically go to the maximum or minimum settings On the other hand if the button is not released gradual adjustment is made until the button is released or until the maximum or minimum...

Страница 7: ...as appropriate WARNING batteries will overheat if fitted incorrectly when fitting the batteries ensure that they are fitted as per the marking on the rear of the holder i e minus of battery against s...

Страница 8: ...the pilot head clear of granules to ensure good cross lighting FUEL BED LAYOUT COAL OPTION One or two packs of 17 coals can be used to enhance the fuel bed on the DGT 5000 burners The first pack of co...

Страница 9: ...of 17 coals can be obtained to lay around the burner unit grille as shown Leave plenty of air gaps between the coals to ensure that the cooling air flow to the underside of the burner is not impeded...

Страница 10: ...les on top of the burner area of the fire FUEL BED LAYOUT EXTRA PEBBLE OPTION An extra pack of 17 pebbles can be obtained to lay around the burner unit grille as shown Leave plenty of air gaps between...

Страница 11: ...Regulations 1998 as amended The chimney or flue should be checked annually to ensure clearance of combustion products Ventilation in the United Kingdom This appliance does not normally require purpose...

Страница 12: ...n optional extra together with a dedicated rechargeable system Data Label Location Behind trim Gas Connection 8 mm OD Tube SECTION SIX Regulations and Warnings THIS APPLIANCE MUST ONLY BE INSTALLED IN...

Страница 13: ...re a small fireplace opening together with a larger diameter flue to give the limited flue height sufficient draw to clear the products of combustion successfully A smooth gather into the flue liner o...

Страница 14: ...ing an internal canopy to the fireplace can be one option to reduce the frontal opening area and to improve the spillage Ventilation must also be checked to ensure it is adequate for products of combu...

Страница 15: ...erial shelf mounted in position temporarily and check the temperature rise does not exceed 80 degrees C above the ambient room temperature at any time in up to six hours of burning N B A minimum clear...

Страница 16: ...Remove the battery compartment by lifting it out of the firebox Remove the top grille from the fire by removing the 4 securing screws Remove the burner unit by lifting it out right hand side first Re...

Страница 17: ...as supply The flue is also accessible from above the appliance Therefore the simplest way to discretely secure the firebox is to fix it in position using silicone adhesive sealant or similar under the...

Страница 18: ...d with the fan running If there is a connected room with an extractor fan the test should be repeated with all the doors to that room opened and the extractor fan running COMPLETION OF INSTALLATION De...

Страница 19: ...terial The loose fuel bed components are delicate and they should be handled with great care They may be removed for cleaning They can be brushed very gently with a soft brush to remove dust or any de...

Страница 20: ...ion from the electronic control box 4 Remove ignition lead from pilot assembly 4 Remove the two screws securing the oxy pilot to the burner 5 Before replacing ensure the code number for Oxy Pilot repl...

Страница 21: ...which is located on a swing tab under appliance Retailer Name ___________________________________________ Address ________________________________ ___________________________________________ ________...

Страница 22: ...LT5032 01 05 08 22 Blank Page...

Страница 23: ...4QJ YOUR DETAILS Name ________________________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model C J DGT 5000 Serial No Date of Purchase This information c...

Страница 24: ...ire Box Labels Spillage Text Data Badge Burner Tray Box Assembly Warning Label Fire Guard Granules Set x 2 black white Vermiculite bag x 1 Restrictor Elbow and PTP Battery 9V PP3 Remote Control Hand S...