Handling and Setting up (pictures 

���

 and 

���

)

Pumps that have reached operating temperature
may have a surface temperature at position (Q)

of more than 70°C.
WARNING! Do Not Touch.
Filter housing (D), oil filler ports (H, H

1

), oil sight glass (I),

oil drain plugs (K, K

1

), gas ballast (U) and oil separator

housing (T) must all be easily accessible. The cooling air
entries (E) and the cooling air exits (F) must have a
minimum distance of 20 cm from any obstruction. The
discharged cooling air must not be re-circulated. For
maintenance purposes we recommend a space of 0.5 m
in front of the filter housing and oil separator.
The VCAH and VCEH pumps can only be operated
reliably if they are installed horizontally.

For installations that are higher than 1000 m
above sea level there will be a loss in capacity.

For further advice please contact your supplier.
When installed on a solid base, the pumps may be
installed without fixing down. If the pumps are installed on
a base plate we would recommend fitting anti vibration
mounts. This range of vacuum pumps are almost vibration
free in operation.

Installation  (pictures

���

 and 

���

)

For operating and installation follow any relevant national standards that are in operation.

1. The vacuum connection (A) is situated on the filter housing (D).

The air handled can be emitted into the atmosphere through the exhaust port (B) or by utilising an exhaust pipe.

Long and/or small bore pipework should be avoided as this tends to reduce the capacity of the pump.
The exhaust port (B) must not be obstructed or partly obscured.

2. The lubricating oil (for recommended brands see under servicing) can be put into the pump at the oil filler port (H) of the oil separator housing,

until the oil level shows at the upper mark of the oil sight glass (l). After filling, make sure the oil filler port is closed.

3. The electrical data can be found on the data plate (N) or the motor data plate. The motors correspond to DIN/VDE 0530 and have IP 54

protection and insulation class B or F. The connection diagram can be found in the terminal box on the motor (unless a special plug connection
is fitted). Check the electrical data of the motor for compatibility with your available supply (voltage, frequency, permissible current etc.).

4. Connect the motor via a motor starter. It is advisable to use thermal overload motor starters to protect the motor and wiring.  All cabling  used

on starters should be secured with good quality cable clamps.
We recommend that motor starters should be used that are fitted with a time delayed trip resulting from running beyond the amperage setting.
When the unit is started cold, overamperage may occur for a short time.

5. Unloading valves (optional extra)

If a vacuum pump is started utilising a star/delta starter it is an advantage to fit an unloading valve; when starting the pump on star the unloading
valve opens and unloads the start of the pump.  When the motor has reached normal speed it is switched into delta, the valve closes and the
pump begins to evacuate the system.

The electrical installation may only be made by a qualified electrician under the observance
of EN 60204. The main switch must be provided by the operator.

Initial Operation (pictures

���

 and 

���

)

1. Initially switch the pump on and off for a few seconds to check the direction of rotation against the

direction arrow (O).

2. Run the pump for two minutes using the correct rotation. Stop pump and top up the oil using the oil filler

port (H) to the correct level (see sight glass (l)). Repeat this process until the oil cooler is completely full.
On no account open the oil filler port when the pump is operating.

3. Connect the suction pipe at (A).
4. Vacuum regulating valve (optional extra):

The vacuum can be adjusted by turning the regulating valve according to the symbols as indicated on
the top of the regulating valve.

Potential risks for operating personnel
1. Noise Emission: The worst noise levels considering direction and intensity measured according to DIN

45635 part 3 (as per 3. GSGV) are shown in the table at the back. When working permanently in the
vicinity of an operating pump we recommend wearing ear protection to avoid any damage to hearing.

2. Oil mist in the Exhaust Stream: Even with the high efficiency oil mist eliminator the exhausted air could

still contain extremely low amounts of oil mist which can occasionally be detected by smell. Permanent
inhalation of these mists may result in health problems, therefore it is extremely important to make sure
that the installation area is well ventilated.

Содержание VCAH 100

Страница 1: ...kuummeter Verwendung Die Vakuumpumpen VCAH und VCEH sind f r den Einsatz im gewerblichen Bereich geeignet d h die Schutzeinrichtungen entsprechen EN DIN 294 Tabelle 4 f r Personen ab 14 Jahren Die Typ...

Страница 2: ...frequenz zul ssige Stromst rke 4 Motor ber Motorschutzschalter anschlie en zur Absicherung ist ein Motorschutzschalter und zur Zugentlastung des Anschlu Kabels ist eine Pg Verschraubung vorzusehen Wir...

Страница 3: ...u abgelassen werden Es d rfen nur Schmier le entsprechend DIN 51506 Gruppe VC VCL oder ein von Rietschle freigegebenes synthetisches l eingesetzt werden Die Viskosit t des les mu ISO VG 100 nach DIN 5...

Страница 4: ...ngsgummis sind verschlissen siehe Wartung 6 2 Das Pumpengeh use ist verschlissen Rattermarken Abhilfe Reparatur durch Hersteller oder Vertragswerkstatt 6 3 Das Vakuum Regulierventil falls vorhanden fl...

Страница 5: ...uired Vacuum regulating valve ZRV additional non return valve ZRK dust inlet filter ZFP high vacuum suction filter ZVF direct on line DOL motor starter ZMS star delta starter ZSG unloading valve for s...

Страница 6: ...for compatibility with your available supply voltage frequency permissible current etc 4 Connect the motor via a motor starter It is advisable to use thermal overload motor starters to protect the mot...

Страница 7: ...R see oil drain plug K1 Only oils corresponding to DIN 51506 group VC VCL or a synthetic oil obtainable from Rietschle should be used The viscosity must corre spond to ISO VG 100 according to DIN 515...

Страница 8: ...orn see under servicing 6 2 The pump cylinder is worn Solution send your complete unit off for repair to the supplier or approved service agent 6 3 The vacuum regulating valve if fitted is noisy Solut...

Страница 9: ...ngle ZSG d chargeded marrage ZAE et vacuom tre Application Ces appareils VCAH et VCEH ne peuvent tre utilis s que dans une aire industrielle c est dire r pondant aux protections pr vues par EN DIN 294...

Страница 10: ...fr quence intensit 4 Relier le moteur un disjoncteur pour sa protection et bloquer le c ble d alimentation par un presse toupe Nous recommandons un disjoncteur coupure temporis e pouvant supporter un...

Страница 11: ...e doit r pondre l ISO VG 100 DIN 51519 Huiles Rietschle recommand es MULTI LUBE 100 huile min rale et SUPER LUBE 100 huile synth tique voir aussi la plaque de recom mandation des huiles M En cas de fo...

Страница 12: ...ce 6 2 Le corps de pompe est us facettes Solution reprise du corps de pompe par le constructeur ou un r parateur 6 3 La valve de r glage si pr sente vibre Solution remplacer la valve 6 4 Les palettes...

Страница 13: ...mento a vuoto ZAE e vuotometro Impiego Le macchineVCAH e VCEH sono adatte per utilizzo in campo industriale per cui i dispositivi di protezione sono conformi alle normative EN DIN 294 tabella 4 per pe...

Страница 14: ...n previsto nell esecuzione con attacco a spina Confrontare i dati motore con la rete corrente tensione frequenza di rete corrente ammissibile 4 Collegare il motore tramite salvamotore prevedere per si...

Страница 15: ...orme a ISO VG 100 secondo DIN 51519 Oli Rietschle consigliati MULTI LUBE 100 olio minerale e SUPER LUBE 100 olio sintetico vedere anche targhetta oli consigliati M In caso di elevato carico termico su...

Страница 16: ...ommini sono usurati Vedere Manutenzione 6 2 La carcassa della pompa usurata rigatura Rimedio riparazione a cura del produttore o officina autorizzata 6 3 La valvola di regolazione vuoto vibra quando i...

Страница 17: ...net for anvendelse i erhvervsm ssigt jemed hvilket betyder at sikkerheds bestemmelser efter EN DIN 294 tabel 4 for personer over 14 r er g ldende VCA og VCE anvendes til evakuering af lukkede beholder...

Страница 18: ...ts data Der anvendes normalt en flangemotor efter VDE DIN 0530 IP 54 isolationsklasse B eller F Monterings vejledning er indlagt i klemmekasse for motorer leveret uden kabel og stik 4 Der skal altid a...

Страница 19: ...SUPER LUBE 100 syntetisk olie P pumpen er anbragt et skilt M hvor olietyper en angivet Ved h j termisk belastning n r omgivelsestemperaturen eller temperaturen p den indsugede luft er over 30 C eller...

Страница 20: ...r denne st j forsvinder n r pumpe bliver varm 6 1 Koblingsgummi er slidt se vedligehold og reparation 6 2 Pumpehus er slidt b lger i cylinder Afhj lpning lad pumpe hovedreparere hos os eller hos autor...

Страница 21: ...iligingen conform EN DIN 294 zijn volgens tabel 4 voor personen boven de 14 jaar De typen zijn geschikt voor het evacueren van gesloten systemen of voor een continue vacu m in de volgende bereiken 50...

Страница 22: ...ning netfrequentie toelaatbare stroomsterkte 4 De motor dient middels een motorbeveiligingsschakelaar te worden aangesloten op het elektriciteitsnet voor de beveiliging van de motor dient de motorbeve...

Страница 23: ...eeroli n gebruikt worden die voldoen aan DIN 51506 groep VC VCL of synthetische oli n die door Rietschle zijn goedgekeurd De viscositeit van de olie moet voldoen aan ISO VG 100 volgens DIN 51519 Aanbe...

Страница 24: ...tart is normaal en dient bij een stijgende pomptemperatuur na 2 minuten te verdwijnen 6 1 De koppelingsrubbers zijn versleten zie onderhoud 6 2 Het pomphuis is versleten wasbord Oplossing reparatie do...

Страница 25: ...seguintes acess rios opcionais V lvula de regula o de v cuo ZRV v lvula anti retorno ZRK filtro separador de poeiras ZFP pr filtro de protec o na aspira o ZVF discontactor para arranque directo ZMS a...

Страница 26: ...l Tens o Frequ ncia Corrente admissivel etc 4 Ligue o motor atrav s dum discontactor Aconselhamos a utilizar um rel t rmico para proteger o motor e a cablagem No caso de utilizar um discontactor este...

Страница 27: ...tico adquir vel na Rietschle A viscosidade tem de corresponder ISO VG 100 de acordo com a norma DIN 51519 Recomendamos o leo Rietschle tipo MULTI LUBE 100 leo mineral SUPER LUBE 100 leo sint tico ou...

Страница 28: ...nta a temperatura de funcionamento 6 1 As borrachas do acoplamento est o danificadas veja o t tulo assist ncia 6 2 O cilindro da bomba est danificado Solu o Enviar a unidade completa para ser reparada...

Страница 29: ...orios opcionales V lvula reguladora de vac o ZRV v lvula antirretorno adicional ZRK filtro de polvo de admisi n ZFP filtro de aspiraci n de vac o ZVF guardamotor de arranque directo ZMS y varios indic...

Страница 30: ...fe especial Verificar que los datos el ctricos del motor sean compatibles con la red disponible tensi n frecuencia tensi n permitida etc 4 Conectar el motor a trav s de un guardamotor Se recomienda ut...

Страница 31: ...eite K1 S lo deben utilizarse aceites que corresponden a DIN 51506 VC VCL o aceite sint tico que puede adquirirse a Rietschle La viscosidad debe corresponder a ISO VG 100 de acuerdo con DIN 51519 Los...

Страница 32: ...minutos con el aumento de la temperatura de funcionamiento 6 1 Los casquillos est n desgastados ver mantenimiento 6 2 El cilindro de la bomba est desgastado Soluci n enviar la unidad completa al prove...

Страница 33: ...tabell 4 f r personer fr n 14 r och ldre VCAH och VCEH anv nds f r evakuering av slutna beh llare eller f r att uppr tth lla ett h gt konstant vakuum inom f ljande gr nser 50 Hz VCAH 0 5 till 130 mba...

Страница 34: ...och isolationsklass B eller F Kopplingsschema r inlagd i plintl da d motorn levereras utan elkabel Kontrollera att motorns data st mmer verens med eln tets data sp nning str mstyrka frekvens 4 Anv nd...

Страница 35: ...tsvara ISO VG 100 enligt DIN 51519 F r b sta driftsf rh llande rekommenderar vi Rietschle vakuumpumpolja MULTI LUBE 100 mineralolja eller SUPER LUBE 100 syntetisk olja se ven skylt M Vid drift i h ga...

Страница 36: ...r dock upph ra efter ca 2 minuters drift 6 1 Kopplingsgummin r slitna se underh ll 6 2 Pumpcylinder r sliten v gbildning tg rd L t pumpen renoveras av oss eller hos auktoriserad verkstad 6 3 Vakuumreg...

Отзывы: