background image

Ridder Drive Systems

Lorentzstraat 36-38 

3846 AX Harderwijk

P.O. Box 360 

3840 AJ Harderwijk

the Netherlands

T

 +31 (0)341 416 854 

F

 +31 (0)341 416 611

I

 www.ridder.com 

E

 [email protected]

Product Manual

Ridder RB50Eᵖˡᵘˢ Tube motor

265041EN - 2017.06 - V01

Original Product Manual

Содержание RB50EPLUS

Страница 1: ...at 36 38 3846 AX Harderwijk P O Box 360 3840 AJ Harderwijk the Netherlands T 31 0 341 416 854 F 31 0 341 416 611 I www ridder com E info ridder com Product Manual Ridder RB50E Tube motor 265041EN 2017...

Страница 2: ...e to the tube motor 19 4 7 Attach the screen cloth and winding tube 20 5 CONNECT INSTRUCTIONS 5 1 Electrical material 22 5 2 Protection Conditions and starting points 22 5 3 Wiring diagram Single 24 5...

Страница 3: ...l installers with professional competence must do all work safe and responsible 1 3 Warning about discouraged use The conditions that follow are applicable when the RB50E tube motor is used Do not cha...

Страница 4: ...ation Damaged systems must be stopped immediately until they are repaired Do not operate roller screen systems when persons are in the danger zone and can touch the roller screen Monitor the danger zo...

Страница 5: ...escriptions Symbol Description Symbol Description ACS Automatic control system N Neutral wire CB Control box with switch components P20 Journal with 2 flat sides at a distance of 20 mm parallel EM M E...

Страница 6: ...the burn out of the drive if the electric motor becomes too hot The RB50E tube motor is almost entirely water resistant The protection classification of IP55 makes sure that a damp environment has no...

Страница 7: ...ecessary to complete the drive system The illustration and table that follow show an overview of the Ridder components that are applicable to the RB50E tube motor Position Description 1 RB50E tube mot...

Страница 8: ...50 x 50 mm approximately 550039 876 x 50 x 50 mm approximately Tube 50 x 1 5 mm Weight 4 2 kg Electrical Supply voltage 230 V AC 1 phase 50 Hz Maximum current 0 56 A 50 Hz Power 126 W Thermal protect...

Страница 9: ...B50 Diameter of the tube motor in mm VK10 Journal dimensions in mm 10x10 Alternatives P20 width in mm 50 Mains frequency 50 Hz 230 Mains voltage 230 V 3 5 Number of revolutions drive shaft at 50 Hz E...

Страница 10: ...50500 is for the standard VK10 journal The tube of the 550039 tube motor has an extension of 74 mm This makes the RB50E tube motor interchangeable with the RB50 tube motor Installation side of the rol...

Страница 11: ...P20 to VK10 tube motor 550032 550039 The replacement VK10 for the P20 guiding unit There is a special guiding unit for the two installation sides of the roller screen Tube motor 550037 Adapter VK10 t...

Страница 12: ...guiding profile 3 with guiding unit 2 between The purlins A and D OR The purlin A and the foundation C Use 4 bolts M6 11 and self locking nuts 12 to attach the mounting brackets 4 to the guiding prof...

Страница 13: ...l1 4 3 1 6 5mm 4x 25 50 A A 50 25 A A 10 5 6 5 4x 19 5 48 27 5 4 3 2 l1 4 3 3 41 4 3 4 Ridder Drive Systems T 31 0 341 416 854 F 31 0 341 416 611 I www ridder com 13...

Страница 14: ...the foundation C Refer to illustrations 4 3 6 4 3 9 2 Drill the holes of 9 mm for the bolts M8 14 2x or 3x in the purlin A Refer to illustrations 4 3 7 4 3 10 Drill the holes at the correct positions...

Страница 15: ...h the mounting bracket 4 with bolts M8 14 2x or 3x and self locking nuts 15 to the purlin A Refer to illustration 4 3 10 3 Fully tighten the 4 bolts M6 11 and self locking nuts 12 of the mounting brac...

Страница 16: ...e pointed to the guiding unit 2 3 Put the power cable of the tube motor 1 along the long side of the cable carrier bracket 8 4 Move the head 10x10 of the tube motor 1 through the bottom hole 8 1 of th...

Страница 17: ...ition of the cable carrier mounting bracket 7 on the post B This position is equal to the length l1 multiplied by 0 5 to 0 6 Drill the holes for the applicable screws 7 1 or bolts 7 1 into the post B...

Страница 18: ...at the FCP end female connection of the cable carrier 6 Attach this end 6 to the end connector MCP at the cable carrier bracket 8 7 Attach the other end of the cable carrier 6 to the end connector FC...

Страница 19: ...ing piece 16 minimum of 5 2 mm if pop rivets of 5 mm are used 3 Use a pop rivet pliers to attach the pop rivet 18 4 Drill the holes for the other three pop rivets 18 5 Use the pop rivet pliers to atta...

Страница 20: ...ler screen system an angle of inclination of less than 20 from the horizontal baseline is not recommended Refer to illustration 4 7 2 The RB50E tube motor is built in to a smooth circular aluminium tu...

Страница 21: ...reen cloth 20 Make an estimate of the length of l3 Refer to illustrations 4 7 1 4 7 3 4 Cut and discard the cord 20 1 along the distance of L2 of the screen cloth 20 2 Refer to illustrations 4 7 1 4 7...

Страница 22: ...ns and starting points The conditions that follow are applicable to the wiring diagrams The installer makes sure that a motor protection circuit breaker MPCB and other necessary protections are used T...

Страница 23: ...rnal sources Too many cables together The warnings that follow must always be obeyed Parallel connection Parallel connection of RB50E tube motors with electronic limit switch systems is possible Alway...

Страница 24: ...sure that the load is less than the maximum switch contact load for the switch installation relay controls switches and such To change the direction of rotation of RB50E tube motor Interchange the tw...

Страница 25: ...Brown Blue Green Yellow Make sure that the load is less than the maximum switch contact load for the switch installation relay controls switches and such To change the direction of rotation of RB50E t...

Страница 26: ...motor Because of this more time is necessary to let the temperature of the tube motor decrease to the ambient temperature If the tube motor is continuously started and stopped for short periods this...

Страница 27: ...r possibly operates at a too high temperature and can be thermally stopped The lifespan will decrease if the tube motor continuously operates at high temperatures 6 2 Operation An RB50E tube motor can...

Страница 28: ...h Note If the connection is incorrect it is not possible to set the tube motor again 7 3 RB50E limit switch system The RB50E tube motor has an electronic limit switch system with a pulse counter The p...

Страница 29: ...st selected direction after step 3 is immediately set Make sure that this direction is correct for the second end position If the selected direction is incorrect erase the first end position refer to...

Страница 30: ...p 4 4 Push and hold the Down button also Wait for a minimum of 1 second and then go to step 5 5 Hold the Down button and release the programming button Wait for a minimum of 1 second and then go to st...

Страница 31: ...then go to step 4 4 Push and hold the Down button also Wait for a minimum of 1 second and then go to step 5 5 Hold the Down button and release the programming button Wait for a minimum of 1 second and...

Страница 32: ...g unit on the guiding profile A dirty guiding profile can cause irregular operation thus uses more power Do a check for a correctly tightened head of the tube motor Do a check for a not damaged power...

Страница 33: ...se 4 The mains voltage is not correct Solution 4 Refer to the identification information on the tube motor for the correct mains voltage If the mains voltage does not agree contact your supplier Cause...

Страница 34: ...ch installation relay controls switches and such Do a check of the conditions and starting points in 6 1 Is the duty cycle correct Problem 3 The second end position is not set after the programming bu...

Страница 35: ...Systems after their lifespan and obey the applicable national and or local regulations 10 2 Decommissioning and removal Decommissioning and removal is only permitted to approved personnel Ridder Driv...

Страница 36: ...www ridder com...

Отзывы: