B
[00FF]: Detailed error code
Cache access error in the CPU
• Defective CPU
• Defective local bus
1. Turn the main power switch off and on.
2. Reinstall the system program.
3. Replace the controller board.
B
[0601, 0602, 0605, 0606, 0607, 0609]: Detailed error code
Exceptional command does not
operate even though it is executed on
purpose.
• Defective CPU devices
1. Replace the controller board.
B
[060A-060E]: Detailed error code
Cut-in command does not operate
when it is executed.
• Defective CPU devices
• Defective ASIC devices
1. Replace the controller board.
B
[0610]: Detailed error code
Timer cut-in does not operate even
though it is set.
• Defective CPU devices
1. Replace the controller board.
B
[0612]: Detailed error code
Cut-in in ASIC occurs.
• Defective ASIC
• Defective devices in which ASIC
detects cut-in.
1. Replace the controller board.
B
[06FF]: Detailed error code
The pipeline clock frequency rate is
different from the prescribed value.
• Defective CPU devices
• Mode bit data error, which is used for
initializing CPU.
1. Replace the controller board.
6. Troubleshooting
164
6
Содержание S-C4.5
Страница 1: ...Model S C4 5 Machine Code D115 D116 Field Service Manual 26 November 2010...
Страница 2: ......
Страница 46: ...26 Reassemble the copier 27 Plug in the power cord and check the operation 2 Installation 44 2...
Страница 64: ...Installation Procedure 1 Open the right door A 2 Interface cover B x 1 3 Rear cover C x 5 2 Installation 62 2...
Страница 69: ...3 Preventive Maintenance Maintenance Tables See Appendices for the following information PM tables 67 3...
Страница 102: ...9 ID sensor I x 1 Discharge plate 1 Right door p 73 2 Discharge plate A 4 Replacement and Adjustment 100 4...
Страница 110: ...Other Replacements Duplex Motor 1 Rear cover p 71 2 Duplex motor A x 1 x 2 4 Replacement and Adjustment 108 4...
Страница 112: ...PSU 1 Open the front door 2 Copy tray p 71 3 PSU assembly A x 4 x 8 4 PSU B x 4 x 6 4 Replacement and Adjustment 110 4...
Страница 134: ...4 Replacement and Adjustment 132 4...
Страница 152: ...5 System Maintenance Reference 150 5...
Страница 181: ...BICU LED Display Number Function LED2 LED2 blinks in normal operation Electrical Component Defects 179 6...
Страница 186: ...6 Troubleshooting 184 6...
Страница 194: ...MEMO 192 EN...
Страница 195: ...Model S C4 5 Machine Code D115 D116 Appendices 26 November 2010...
Страница 196: ......