Code
Meaning
Suggested Cause/Action
6-05
G3 ECM - facsimile data frame
not received within 18 s of CFR,
but there was no line fail
• Check the line connection.
• Check for a bad line or defective remote terminal.
• Replace the FCU.
• Try adjusting the rx cable equalizer
Cross reference
• Rx cable equalizer - G3 Switch 07 (PSTN)
6-06
G3 ECM - coding/decoding
error
• Defective FCU.
• The other terminal may be defective.
6-08
G3 ECM - PIP/PIN received in
reply to PPS.NULL
• The other end pressed Stop during communication.
• The other terminal may be defective.
6-09
G3 ECM - ERR received
• Check for a noisy line.
• Adjust the tx levels of the communicating machines.
• See code 6-05.
6-10
G3 ECM - error frames still
received at the other end after
all communication attempts at
2400 bps
• Check for line noise.
• Adjust the tx level (use NCU parameter 01 or the
dedicated tx parameter for that address).
• Check the line connection.
• Defective remote terminal.
6-21
V.21 flag detected during high
speed modem communication
• The other terminal may be defective or incompatible.
6-22
The machine resets the
sequence because of an
abnormal handshake in the V.
34 control channel
• Check for line noise.
• If the same error occurs frequently, replace the FCU.
• Defective remote terminal.
6-99
V.21 signal not stopped within
6 s
• Replace the FCU.
13-17
SIP user name registration error
• Double registration of the SIP user name.
• Capacity for user-name registration in the SIP server is
not sufficient.
4. Appendix: Fax Troubleshooting Guide
138
4
Содержание S-C4.5
Страница 1: ...Model S C4 5 Machine Code D115 D116 Field Service Manual 26 November 2010...
Страница 2: ......
Страница 46: ...26 Reassemble the copier 27 Plug in the power cord and check the operation 2 Installation 44 2...
Страница 64: ...Installation Procedure 1 Open the right door A 2 Interface cover B x 1 3 Rear cover C x 5 2 Installation 62 2...
Страница 69: ...3 Preventive Maintenance Maintenance Tables See Appendices for the following information PM tables 67 3...
Страница 102: ...9 ID sensor I x 1 Discharge plate 1 Right door p 73 2 Discharge plate A 4 Replacement and Adjustment 100 4...
Страница 110: ...Other Replacements Duplex Motor 1 Rear cover p 71 2 Duplex motor A x 1 x 2 4 Replacement and Adjustment 108 4...
Страница 112: ...PSU 1 Open the front door 2 Copy tray p 71 3 PSU assembly A x 4 x 8 4 PSU B x 4 x 6 4 Replacement and Adjustment 110 4...
Страница 134: ...4 Replacement and Adjustment 132 4...
Страница 152: ...5 System Maintenance Reference 150 5...
Страница 181: ...BICU LED Display Number Function LED2 LED2 blinks in normal operation Electrical Component Defects 179 6...
Страница 186: ...6 Troubleshooting 184 6...
Страница 194: ...MEMO 192 EN...
Страница 195: ...Model S C4 5 Machine Code D115 D116 Appendices 26 November 2010...
Страница 196: ......