0-1
Inch-mm conversion before tx
Bit 1: 0, Bit 0: 0 = Inch-mm
conversion available
Bit 1: 0, Bit 0: 1 = Inch only
Bit 1: 1, Bit 0: 0 = Not used
Bit 1: 1, Bit 0: 1 = Disabled
The machine uses inch-based resolutions for scanning. If
"inch only" is selected, the printed copy may be slightly
distorted at the other end if that machine uses mm-based
resolutions.
If the setting is "Disabled", the bit switch setting is used.
2-3
DIS/NSF detection method
Bit 3: 0, Bit 2: 0 = First DIS or NSF
Bit 3: 0, Bit 2: 1 = Second DIS or
NSF
Bit 3: 1, Bit 2: 0 = Not used
Bit 3: 1, Bit 2: 1 = Disabled
(0, 1): Use this setting if echoes on the line are interfering
with the set-up protocol at the start of transmission. The
machine will then wait for the second DIS or NSF before
sending DCS or NSS.
If the setting is "Disabled", the bit switch setting is used.
4
V.8 protocol
0: Off
1: Disabled
If transmissions to a specific destination always end at a
lower modem rate (14,400 bps or lower), disable V.8
protocol so as not to use V.34 protocol.
0: V.34 communication will not be possible.
If the setting is "Disabled", the bit switch setting is used.
5
Compression modes available in
transmit mode
0: MH only
1: Disabled
This bit determines the capabilities that are informed to the
other terminal during transmission.
If the setting is "Disabled", the bit switch setting is used.
6-7
ECM during transmission
Bit 7: 0, Bit 6: 0 = Off
Bit 7: 0, Bit 6: 1 = On
Bit 7: 1, Bit 6: 0 = Not used
Bit 7: 1, Bit 6: 1 = Disabled
For example, if ECM is switched on but is not wanted when
sending to a particular terminal, use the (0, 0) setting.
• V.8/V.34 protocol and JBIG compression are
automatically disabled if ECM is disabled.
• If the setting is "Disabled", the bit switch setting is used.
Switch 04 - Not used (do not change the settings)
Switch 05 - Not used (do not change the settings)
Switch 06 - Not used (do not change the settings)
Switch 07 - Not used (do not change the settings)
Dedicated Transmission Parameters
227
5
Содержание S-C4.5
Страница 1: ...Model S C4 5 Machine Code D115 D116 Field Service Manual 26 November 2010...
Страница 2: ......
Страница 46: ...26 Reassemble the copier 27 Plug in the power cord and check the operation 2 Installation 44 2...
Страница 64: ...Installation Procedure 1 Open the right door A 2 Interface cover B x 1 3 Rear cover C x 5 2 Installation 62 2...
Страница 69: ...3 Preventive Maintenance Maintenance Tables See Appendices for the following information PM tables 67 3...
Страница 102: ...9 ID sensor I x 1 Discharge plate 1 Right door p 73 2 Discharge plate A 4 Replacement and Adjustment 100 4...
Страница 110: ...Other Replacements Duplex Motor 1 Rear cover p 71 2 Duplex motor A x 1 x 2 4 Replacement and Adjustment 108 4...
Страница 112: ...PSU 1 Open the front door 2 Copy tray p 71 3 PSU assembly A x 4 x 8 4 PSU B x 4 x 6 4 Replacement and Adjustment 110 4...
Страница 134: ...4 Replacement and Adjustment 132 4...
Страница 152: ...5 System Maintenance Reference 150 5...
Страница 181: ...BICU LED Display Number Function LED2 LED2 blinks in normal operation Electrical Component Defects 179 6...
Страница 186: ...6 Troubleshooting 184 6...
Страница 194: ...MEMO 192 EN...
Страница 195: ...Model S C4 5 Machine Code D115 D116 Appendices 26 November 2010...
Страница 196: ......