• Auto Off: 1 min.
• Low power: 15 min.
The machine goes to Low Power mode after 1 minute. Off/Sleep mode is not used.
Recommendation
We recommend that the default settings should be kept.
• If the customer requests that these settings should be changed, please explain that their energy costs
could increase, and that they should consider the effects on the environment of extra energy use.
• If it is necessary to change the settings, please try to make sure that the Auto Off timer is not too long.
Try with a shorter setting first, such as 30 min., then go to a longer one (such as 60 min.) if the customer
is not satisfied.
• If the timers are all set to the maximum value, the machine will not begin saving energy until 240
minutes has expired after the last job. This means that after the customer has finished using the machine
for the day, energy will be consumed that could otherwise be saved.
• If you change the settings, the energy consumed can be measured using SP8941, as explained below.
Energy Save Effectiveness
SP 8941 (Machine Status) keeps a record of the amount of time that the machine spends in each mode.
• 8941-001: Operating mode
• 8941-002: Standby mode
• 8941-003: Panel off mode
• 8941-004: Low power mode
• 8941-005: Off/sleep mode
With this data, and the power consumption values from the specifications, we can estimate the amount of
energy that is used by the machine.
This should only be used as a reference value, because the power consumption specifications are measured
in a controlled environment with a constant power supply.
To get an exact measurement at the customers site, a watt meter must be used to measure the actual energy
consumed.
To use SP8941 to calculate the energy consumed:
• At the start of the measurement period, read the values of SP8941 001 to 005.
• At the end of the measurement period, read the values of SP8941 001 to 005 again.
• Find the amount of time spent in each mode (subtract the earlier measurement from the later
measurement).
7. Energy Saving
186
7
Содержание S-C4.5
Страница 1: ...Model S C4 5 Machine Code D115 D116 Field Service Manual 26 November 2010...
Страница 2: ......
Страница 46: ...26 Reassemble the copier 27 Plug in the power cord and check the operation 2 Installation 44 2...
Страница 64: ...Installation Procedure 1 Open the right door A 2 Interface cover B x 1 3 Rear cover C x 5 2 Installation 62 2...
Страница 69: ...3 Preventive Maintenance Maintenance Tables See Appendices for the following information PM tables 67 3...
Страница 102: ...9 ID sensor I x 1 Discharge plate 1 Right door p 73 2 Discharge plate A 4 Replacement and Adjustment 100 4...
Страница 110: ...Other Replacements Duplex Motor 1 Rear cover p 71 2 Duplex motor A x 1 x 2 4 Replacement and Adjustment 108 4...
Страница 112: ...PSU 1 Open the front door 2 Copy tray p 71 3 PSU assembly A x 4 x 8 4 PSU B x 4 x 6 4 Replacement and Adjustment 110 4...
Страница 134: ...4 Replacement and Adjustment 132 4...
Страница 152: ...5 System Maintenance Reference 150 5...
Страница 181: ...BICU LED Display Number Function LED2 LED2 blinks in normal operation Electrical Component Defects 179 6...
Страница 186: ...6 Troubleshooting 184 6...
Страница 194: ...MEMO 192 EN...
Страница 195: ...Model S C4 5 Machine Code D115 D116 Appendices 26 November 2010...
Страница 196: ......