4-7
Modem setting for reception
Sets the modem type for reception. The default is "0100" (V27ter, V29, V17).
Bit 7
Bit 6
Bit 5
Bit 4
0
0
0
1
V27ter
0
0
1
0
V27ter, V29
0
0
1
1
V27ter, V29, V33
(invalid)
0
1
0
0
V27ter, V29, V17
0
1
0
1
V27ter, V29, V17,
V34*
*V34 is not supported for IP-Fax communication.
IP Fax Switch 07 [SP No. 1-111-008]
No.
FUNCTION
COMMENTS
0
TSI information
0: Not added, 1: Added
Adds or does not add TSI information to NSS(S).
1
DCN transmission setting at T1 timeout
0: Not transmitted,
1: Transmitted
Transmits or does not transmit DCN at T1 timeout.
2
Not used
Do not change this setting.
3
Hang up setting at DIS reception
disabled
0: No hang up
1: Hang up after transmitting DCN
Sets whether the machine disconnects after DIS
reception.
4
Number of times for training
0: 1 time, 1: 2 times
Selects the number of times training is done at the
same bit rate.
5
Space CSI transmission setting at no CSI
registration
0: Not transmitted,
1: Transmitted
When "0" is selected, frame data is enabled.
When "1" is selected, the transmitted data is all
spaces.
Bit Switches
207
5
Содержание S-C4.5
Страница 1: ...Model S C4 5 Machine Code D115 D116 Field Service Manual 26 November 2010...
Страница 2: ......
Страница 46: ...26 Reassemble the copier 27 Plug in the power cord and check the operation 2 Installation 44 2...
Страница 64: ...Installation Procedure 1 Open the right door A 2 Interface cover B x 1 3 Rear cover C x 5 2 Installation 62 2...
Страница 69: ...3 Preventive Maintenance Maintenance Tables See Appendices for the following information PM tables 67 3...
Страница 102: ...9 ID sensor I x 1 Discharge plate 1 Right door p 73 2 Discharge plate A 4 Replacement and Adjustment 100 4...
Страница 110: ...Other Replacements Duplex Motor 1 Rear cover p 71 2 Duplex motor A x 1 x 2 4 Replacement and Adjustment 108 4...
Страница 112: ...PSU 1 Open the front door 2 Copy tray p 71 3 PSU assembly A x 4 x 8 4 PSU B x 4 x 6 4 Replacement and Adjustment 110 4...
Страница 134: ...4 Replacement and Adjustment 132 4...
Страница 152: ...5 System Maintenance Reference 150 5...
Страница 181: ...BICU LED Display Number Function LED2 LED2 blinks in normal operation Electrical Component Defects 179 6...
Страница 186: ...6 Troubleshooting 184 6...
Страница 194: ...MEMO 192 EN...
Страница 195: ...Model S C4 5 Machine Code D115 D116 Appendices 26 November 2010...
Страница 196: ......