Address
Function
Unit
Remarks
680578
Minimum required length of the second
and subsequent rings
20 ms
SP2-103-009 (parameter
08).
680579
Ringing signal detection reset time
(LOW)
20 ms
SP2-103-010 (parameter
09).
68057A
Ringing signal detection reset time
(HIGH)
SP2-103-011 (parameter
10).
68057B
to
680580
Not used
-
Do not change the settings.
680581
Interval between dialing the last digit
and switching the Oh relay over to the
external telephone when dialing from
the operation panel in handset mode.
20 ms
Factory setting: 500 ms
680582
Bits 0 and 1 - Handset off-hook detection time
Bit 1:0, Bit 0: 0 = 200 ms
Bit 1:0, Bit 0: 1 = 800 ms
Other Not used
Bits 2 and 3 - Handset on-hook detection time
Bit 3: 0, Bit 2: 0 = 200 ms
Bit 3: 0, Bit 2: 1 = 800 ms
Other Not used
Bits 4 to 7 - Not used
-
680583
To
6805A0
Not used
-
Do not change the settings.
6805A1
Acceptable CED detection frequency
upper limit (high byte)
BCD (Hz)
If both addresses contain FF
(H), tone detection is
disabled.
6805A2
Acceptable CED detection frequency
upper limit (low byte)
5. Appendix: Fax Service Program
218
5
Содержание S-C4.5
Страница 1: ...Model S C4 5 Machine Code D115 D116 Field Service Manual 26 November 2010...
Страница 2: ......
Страница 46: ...26 Reassemble the copier 27 Plug in the power cord and check the operation 2 Installation 44 2...
Страница 64: ...Installation Procedure 1 Open the right door A 2 Interface cover B x 1 3 Rear cover C x 5 2 Installation 62 2...
Страница 69: ...3 Preventive Maintenance Maintenance Tables See Appendices for the following information PM tables 67 3...
Страница 102: ...9 ID sensor I x 1 Discharge plate 1 Right door p 73 2 Discharge plate A 4 Replacement and Adjustment 100 4...
Страница 110: ...Other Replacements Duplex Motor 1 Rear cover p 71 2 Duplex motor A x 1 x 2 4 Replacement and Adjustment 108 4...
Страница 112: ...PSU 1 Open the front door 2 Copy tray p 71 3 PSU assembly A x 4 x 8 4 PSU B x 4 x 6 4 Replacement and Adjustment 110 4...
Страница 134: ...4 Replacement and Adjustment 132 4...
Страница 152: ...5 System Maintenance Reference 150 5...
Страница 181: ...BICU LED Display Number Function LED2 LED2 blinks in normal operation Electrical Component Defects 179 6...
Страница 186: ...6 Troubleshooting 184 6...
Страница 194: ...MEMO 192 EN...
Страница 195: ...Model S C4 5 Machine Code D115 D116 Appendices 26 November 2010...
Страница 196: ......