Rigel-PJ1nx Training
Slide 41
Starting the Projector when the Top Cover
and Lamp Cover have been Removed - 1
The lamp cover switch is mounted on the main board.
The projector cannot be started if the lamp cover and top
cover have been removed.
Prepare a strip of cardboard as shown on the left.
Length: 35 to 40 (mm), Width: 100 to 120 (mm), Thickness:
1 to 2 (mm)
Fold it into a v-shape.