11
Rigel-PJ1nx Training
Slide 11
Lamp Near-end/End Alerts
There is no near-end alert.
The lamp end alert occurs when the machine calculates
that the life time has expired.
If used in Normal Mode only, the alert appears after 3,000
hrs projection time
If used in Eco Mode only, the alert appears after 3,500 hrs
projection time
If the user switches between modes, the machine
calculates when to display the alert based on how long the
lamp was used in each mode.
If the projector is used for 100 hours after the lamp has
reached the end of its life, the projector will turn off and go
into standby mode.
In this condition, the lamp hours cannot be reset using the
menu.
The user must replace the lamp, then press the Help button
on the remote control for 10 seconds to reset the lamp
clock back to zero (do this only after replacing the lamp).
No additional notes