1 October, 1999
PRINTER CONTROLLER ERROR
7-11
Trouble-
shooting
7.2 PRINTER CONTROLLER ERROR
7.2.1 ERROR CODES
Code
Description
Required Action
0201
On-board SDRAM read/verify
failed.
Replace the controller if this error is
frequent.
0301
SDRAM DIMM (option)
read/verify failed.
Replace the SDRAM DIMM if this error is
frequent.
1101
Data transmission did not finish
within the specified time.
An incompatible loop-back connector is
connected to the parallel port, or the
loop-back connector is not connected.
Use the correct loop-back connector
(P/#: G0219350) before the test.
1102
Data looped back to the controller
is not the same as the data
transmitted.
The loop-back connector may be
defective. Try using another one.
11xx
Parallel interface error.
Replace the controller if this error is
frequent.
1401
The controller NVRAM has a
problem.
1402
NVRAM checksum error or the
battery has run out.
1403
NVRAM write error
1404
NVRAM read error
Replace the NVRAM if this error is
frequent.
1501
RTC error
Replace the controller board if this error
is frequent.
1601
Font ROM error
Replace the controller if this error is
frequent.
1602
The data in the Font ROM is
damaged.
Replace the controller if this error is
frequent.
1Bxx
Option bus error A
Check the connection to the optional
component.
Try replacing the optional NIB or HDD.
1Cxx
Option bus error B
Check the connection to the optional
component.
Try replacing the optional NIB or HDD.
2100
NIB self test failed.
Turn off the machine and turn it back on.
Replace the NIB if this error is frequent.
21xx
NIB error
2501
The data in the PS DIMM is
damaged.
Replace the PS DIMM if this error is
frequent.
2508
The data in the IC card is
damaged.
Reprogram the IC card and try again.
3002
A damaged cluster was found on
the HDD.
The damaged cluster is automatically
marked as “bad”.
If this error is frequent, format the HDD.
47xx
Controller ASIC error.
Replace the controller.