background image

Declaration about the Contamination of 
Richter Pumps, -Valves 
and Components 

Prepared: 

CRQ/Lam 

on:

 

Feb. 15, 06

 

Page:

 2 

QM

 

No.: 

0912-16-2001_en/4-

06

 

Approved:

 CRQ/Zu 

on:

 Feb. 

15, 

06

 

of

 

:

2

The repair and/or maintenance of pumps, valves and components can only be implemented if a completely filled out 
declaration is available. If this is not the case, delay of the work will occur. If this declaration is not attached to the 
devices, which have to be repaired, the transmission can be rejected. 

Every aggregate has to have it’s own declaration.

This declaration may be filled out and signed only by authorized technical personnel of the operator. 

 

Contractor/dep./institute : 

 

Reason for transmitting       

Please mark the applicable 

Repair:

 

subject to fee 

Warranty 

Street : 

 

Exchange:

 

subject to fee 

Warranty 

Postcode, city: 

 

Exchange/ Replacement already initiated/received 

Contact person: 

 

Return

:

Leasing 

Loan 

for credit note 

Phone : 

Fax : 

 

 

End user

 : 

 

A.  Details of Richter-product: 

 

Failure description: 

Classification:  

 

Article number: 

 

 

Equipment: 

Serial number: 

 

 

Application tool: 
Application process: 

B.  Condition of the Richter-product:

no

1)

 

yes 

  no 

 

Contamination : 

 

  no

1)

 yes 

 

Was it in operation ? 

 

toxic  

Drained (product/operating supply item) ? 

 

caustic  

All openings hermetically locked! 

 

inflammable  

Cleaned ? 

 

explosive

2)

 

If yes, with which cleaning agent: 

 

mikrobiological

2

)

and with which cleaning method: 

 

radioactive 

3)

 

1)

 if "no", then forward to

 D

.

other pollutant 

 

2)

 

Aggregates, which are contaminated with microbiological or explosive substances, are only 
accepted with documented evidence of an approved cleaning. 

3)

 

Aggregates, which are contaminated with radioactive substances, are not accepted in principle. 

 

C.  Details of the discharged materials (must be filled out imperatively) 

 

1.

 

With which materials did the aggregate come into contact

 ?

 

Trade name and/or chemical 

designation of operational funds and discharged materials, material properties, e.g. as per 
safety data sheet (e.g. toxic, inflammable, caustic)

 

X Trade name: 

Chemical designation: 

 

a)  

 

b)  

 

c)  

 

d)  

 

no yes 

 

2.  Are the materials specified above harmful to health ? 

 

3.  Dangerous decomposition products during thermal load ? 

 

If yes, which ones ? 

 

D. Mandatory declaration:

We assure that the data in this explanation are truthful and complete and as a signatory I am 

able to form an opinion about this. We are aware that we are responsible towards the contractor for damages, which results 
from incomplete and incorrect data. We commit ourselves to exempt the contractor from claims for damages of thirds 
resulting from incomplete or incorrect data. We are aware that we are directly responsible towards thirds, irrespective of this 
declaration, which belongs in particularly to the employees of the contractor consigned with the handling repair of the product. 

Name of the authorized person 
(in block letters):

 

Date  

Signature 

 

Company stamp 

Содержание ASME Series

Страница 1: ...rt installation operation and maintenance Subject to change without notice Reproduction is generally permitted with indication of the source Richter Chemie Technik GmbH 9250 050 en Revision 11 Edition...

Страница 2: ...Coupling guard 13 5 11 Electric connection 13 6 Commissioning Shutdown 14 6 1 Initial commissioning 14 6 1 1 Filling the pump housing casing 14 6 1 2 Start up 14 6 2 Operating limits 14 6 2 1 Abrasiv...

Страница 3: ...et http www richter ct com Authorised person acc to machinery directive 2006 42 EG Gregor Kleining Designation Single stage plastic lined magnetic drive chemical centrifugal pump series MNKA long life...

Страница 4: ...ws flanges to ASME DN No x size Tightening torque inch ASME Nm in lbs 1 4 x 8 70 1 4 x 15 135 2 4 x S 25 220 3 4 x S 45 400 1 2 Name plate dry running ATEX and housing casing markings The stainless st...

Страница 5: ...e series MNKA ASME are sealless plastic lined magnetic drive centrifugal pumps for the leak free conveyance of aggressive toxic pure and inflammable liquids The pump is equipped with a permanent magne...

Страница 6: ...ring transport and storage of the magnetic drives as single components the notes on safety in Section 7 5 2 must be observed The points listed in Section 6 1 must be followed before recommissioning 2...

Страница 7: ...er 9 3 allows no temperature class or temperature to be indicated The temperature class must be determined by the operated in accordance with Section 2 6 7 Temperature limits 2 6 5 Check of the direct...

Страница 8: ...data sheet The plant customer must ensure that the prescribed operating temperature is observed The maximum admissible temperature of the liquid medium at the pump inlet depends on the temperature cl...

Страница 9: ...as possible Elastomers are to be protected against UV light In general a storage period of 10 years should not be exceeded An admissible storage period of 4 years applies to elastomers made of NBR If...

Страница 10: ...ainment shell chamber is also vented and evacuated through the bores in the plain bearing pedestal 339 Additional information is provided in the brochure and the Product manual 5 Installation 5 1 Safe...

Страница 11: ...sitive suction head must also be observed The NPSHR value required for the pump is specified in the data shee The NPSHR available in the plant should be at least 1 64 ft 0 5 m higher than the NPSHR re...

Страница 12: ...Problems on request 5 7 Drive The power consumption of the pump at the operating design point is specified in the data sheet and works certificate If the operating design point was not known when the...

Страница 13: ...t prevention regulations It must be ensured that the coupling guard used is either made of spark free material or the impact test required by the EN 13463 is satisfied without any reservations Richter...

Страница 14: ...turned by hand Check the direction of rotation of the motor with the coupling disengaged or with a rotary field instrument As viewed from the motor the direction of rotation of the pump is clockwise S...

Страница 15: ...connection with explosion protection potential sources of ignition overheating electrostatic and induced charges mechanical and electric sparks may result from these inadmissible modes of operation t...

Страница 16: ...index approx 85 Kinematic viscosity at 104 F 40 C s 2 mm 40 appr A fully synthetic gear oil to ISO VG 220 is to be used for temperatures below 68 F 20 C Replacing the bearings The ball bearings are de...

Страница 17: ...ta carriers such as credit cards cheque cards ID cards with magnetic strips or magnetic tape 6 150 mm distance 7 6 Dismantling There are 3 possibilities for dismantling 1 Remove the complete pump from...

Страница 18: ...ure that no plain bearing parts fall Silicon carbide is easy to break Use isolated gloves when handling hot bearings Failure to follow this instructions may result in property damage sever personal in...

Страница 19: ...screw 914 1 with tooth lock washer 936 1 Secure thread with a drop of Loctite for example For tightening a hex socket key with 120 mm minimum length is required Screw bearing pedestal 330 lantern 344...

Страница 20: ...ightening the housing casing screws 901 3 make sure that the support bracket 183 is firmly positioned If necessary undo support bracket align and secure again For tightening torques see Section 1 1 7...

Страница 21: ...NPSHR too high Are the pipe resistances too high Is the viscosity too high Is the direction of rotation correct Is the speed too low or the impeller diameter too small Are pump parts worn Gas in the...

Страница 22: ...61 rear bearing cover 400 1 flat gasket 401 housing gasket casing gasket 412 3 O ring 415 1 centering gasket 504 distance ring 509 1 intermediate ring 529 x bearing sleeve 545 x bearing bush 557 2 con...

Страница 23: ...Series MNKA acc to ASME Page 23 9250 050 en Revision 11 TM 7903 Edition 07 2010 9 2 MNKA with long life grease lubrication...

Страница 24: ...Series MNKA acc to ASME Page 24 9250 050 en Revision 11 TM 7903 Edition 07 2010 9 3 MNKA with oil bath lubrication...

Страница 25: ...UMPEN CHEMICAL PROCESS PUMPS POMPE POUR L INDUSTRIE CHIMIQUE Baureihe Series S rie Ausf hrung Magnetkupplungspumpe ASME insatzgrenzen Design Magnet drive pump ASME operating limits Construction Pompe...

Страница 26: ...iled by below mentioned notified body according to directive 94 9 EC Physikalische Technische Bundesanstalt PTB D 38116 Braunschweig Baureihe Series Registrier Nr Registered Baureihe Series Registrier...

Страница 27: ...Interne Fertigungskontrolle Production Quality Assurance Angewandte EN 14121 harmonisierte Normen EN 809 Applied harmonised Standards Kennzeichnung 2006 42 EG Marking Das Unternehmen Richter Chemie T...

Страница 28: ...mination of the pumps valves and component sent in for repair On the basis of this information for the contractor is it possible to meet the necessary preventive action during the execution of the rep...

Страница 29: ...logical 2 and with which cleaning method radioactive 3 1 if no then forward to D other pollutant 2 Aggregates which are contaminated with microbiological or explosive substances are only accepted with...

Страница 30: ...IOSTOFFV the procedures for the prevention of accidents as well as regulations to environmental protection e g the Waste Management Law AbfG and the Water Resources Act WHG An inspection repair of Ric...

Отзывы: