Operation
© Rice Lake Weighing Systems
●
All Rights Reserved
31
Digital Inputs Status
Bit a 1: input high; Bit a 0: input is low
Digital Outputs Status
Digital Outputs Command
It allows to control the outputs status in
mode. See
.
Bit a 1: output is closed; Bit a 0: output is open.
Setting bit 15 to 1 on the PLC, DeviceNet takes control of all the outputs, even if they are in different modes.
Status Register
Bit No.
Description
Bit No.
Description
Bit 0
INPUT 1 status
Bit 4
—
Bit 1
INPUT 2 status
Bit 5
—
Bit 2
—
Bit 6
—
Bit 3
—
Bit 7
—
Table 3-6. Digital Inputs (DeviceNet)
Bit No.
Description
Bit No.
Description
Bit 0
OUTPUT 1 status
Bit 4
—
Bit 1
OUTPUT 2 status
Bit 5
—
Bit 2
OUTPUT 3 status
Bit 6
—
Bit 3
—
Bit 7
—
Table 3-7. Digital Outputs (DeviceNet)
Bit No.
Description
Bit No.
Description
Bit 0
OUTPUT 1 status
Bit 8
—
Bit 1
OUTPUT 2 status
Bit 9
—
Bit 2
OUTPUT 3 status
Bit 10
—
Bit 3
—
Bit 11
—
Bit 4
—
Bit 12
—
Bit 5
—
Bit 13
—
Bit 6
—
Bit 14
—
Bit 7
—
Bit 15
Force Output
Table 3-8. Digital Outputs Command (DeviceNet)
Bit No.
Description
Bit No.
Description
Bit 0
Cell Error
Bit 8
Net weight negative sign
Bit 1
A/D Converter Malfunction
Bit 9
Peak weight negative sign
Bit 2
Maximum weight exceeded by 9 divisions
Bit 10
Net display mode
Bit 3
Gross weight higher than 110% of full scale
Bit 11
Weight stability
Bit 4
Gross weight beyond 999999 or less than -999999
Bit 12
Weight /-¼ of a division around ZERO
Bit 5
Net weight beyond 999999 or less than -999999
Bit 13
—
Bit 6
—
Bit 14
—
Bit 7
Gross weight negative sign
Bit 15
Force Output
Table 3-9. Status Register (DeviceNet)
Note