Configuration
© Rice Lake Weighing Systems
●
All Rights Reserved
25
2.11 Test
1. Press and hold
and .
is
displayed.
2. Press or until
is displayed. Press
.
3. Press or until desired parameter is displayed. Press
.
4. For
and
, current reading is displayed. Press
.
5. For
, press until the corresponding out value change is flashing.
6. Press to change the value. Press
.
7. Press twice to exit set-up menu.
SEt 1
SEt 2
SEt 3
OFF
*
Relay switching will not occur if the setpoint value is ‘0’.
On
Setpoint = ’0’ and nodbus=posneg, relay switching occurs when the weight is ‘0’; the relay will switch again when the
weight is different from zero, taking hysteresis into account (both for positive and for negative weights).
Setpoint = ’0’ and nodes=pos, relay switching occurs for a weight higher than or equal to ‘0’, the relay will switch
again for values below ‘0’, taking hysteresis into account.
Setpoint = ’0’ and nodes=neg, relay switching occurs for a weight lower than or equal to ‘0’, the relay will switch again
for values above ‘0’, taking hysteresis into account.
In 1
In 2
*
(In 2
default)
(NET/GROSS): by closing this input for less than one second, it performs a SEMI-AUTOMATIC TARE and the display
will show the net weight. To display the gross weight again, hold the NET/GROSS input closed for three seconds.
*
(In 1
default)
By closing the input for less than one second, the weight is set to zero (
PEAH
With the input closed the maximum weight value reached remains on display. Opening fthe input the current weight is
displayed.
PLC
Closing the input no operation is performed, the input status may however be read remotely by way of the communi
-
cation protocol.
COntIn
Closing the input for less than one second the weight is transmitted via the serial connection according to the fast
continuous transmission protocol one time only (only if contin is set in the item serial).
COEFF
When the input is closed the weight is displayed based on the set coefficient, otherwise the weight is displayed. See
*
Indicates default value.
Parameter
Options
Description
In
N/A
Input Test - for each open input 0 is displayed, 1 is displayed when
the input is closed.
Out
*
1
Output Test -
Setting 0 opens the corresponding output .
Setting 1 closes the corresponding output .
ANALOG
ANALOG
Allows the analog signal to range between the minimum and the
maximum values starting from the minimum.
NA
Current output test
UOLt
voltage output test
NU-CEL
N/A
Millivolt Test - displays the load cell response signal in mV with four
decimals.
* Indicates default value.
Table 2-16. Test Parameters
Parameter
Options
Description
Table 2-15. Outputs and Inputs Menu Parameters (Continued)