![Rice Lake MSI-8000 Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/rice-lake/msi-8000/msi-8000_technical-manual_1453937027.webp)
ScaleCore Connect
©
Rice Lake Weighing Systems
●
All Rights Reserved
23
Min Sensor Value
– enter min sensor value acceptable
Max Sensor Value
– enter max sensor value acceptable
Not Filtered Sensor Value
– check box is applicable
DAC Offset
– current calibration value
DAC Gain
– current calibration value
DAC Count
– current calibration value
Min DAC Count
– enter min DAC Count acceptable
Max DAC Count
– enter max DAC Count acceptable
Output Mode
– select output mode to be used
Figure 3-10. Output Mode Selections
3. Press
to save.
RF Configuration
Radio Frequency (RF) configuration allows the setup of RF cards available in the products connected.
Figure 3-11. RF Configuration
1. Select
Configuration
, then
RF
.
2. Enter the following parameters:
Status
– select Enabled (default) or Disabled
Channel
– select a channel from 12-23
Network ID
– enter a number from 0-65534 for an ID
Device Type
– select XBee or Other (for all other cards installed)
Power Level
– select a level from 0-4 (only on transmitters; power level does not change on receivers)
Always On
– select Enabled or Disabled (default)
Only set Always On to Enabled when using Rugged Remote. Having this parameter set to Enabled will drain the
battery even when the scale if off. Disconnect the battery when not in use.
3. Press
to save. New settings will not take affect until power is cycled on the product.
Note