1.8 MSI-7000HD Front Panel
Figure 1-3. MSI-7000HD Front Panel
Item No.
Description
1
Setpoint 1-3 Connections – Located on the side of the unit
2
Power Input – Located on the side of the unit
3
Setpoint LEDs
Green – Setpoint is enabled and not tripped
Red – Setpoint is enabled and tripped
Orange – Setpoint configuration error
4
Power Button
5
Power LED – Indicates unit is on when lit
Steady Green – On with good battery (or AC)
Steady Orange – On with low battery
Blinking Red – On with very low battery
6
Zero Button – Press to zero the currently selected channel
7
Arrow Buttons – Use to scroll through channels
8
Calibration Screw – Used when unit is in NTEP mode
9
Channel LEDs – Indicates which channel is being controlled by the unit
Off – Sensor is disabled
Blinking Orange – RF is disconnected
Steady Orange – Sensor fault (overload/underload/uncal/error/etc.)
Blinking Blue – Sensor is in CoZ and working properly
Steady Blue – Sensor is loaded and working properly
Steady Purple – Sensor Selected (for two seconds for zeroing)
10
Communication Ports – Comm Port 1 is pre-set at 9600 baud and 8-N-1; Comm Port 2 is pre-set at 38400 baud and 8-N-1
11
Load Cell Inputs - Located on the side of the unit
Table 1-5. MSI-7000HD Front Panel Controls
CAL
POWER IN
CHANNEL
1
RELAY
2
RELAY
3
CHANNEL
2
CHANNEL
3
CHANNEL
4
2
1
3
4
5
6
7
8
9
10
11
Содержание MSI-8000
Страница 49: ......