![Rice Lake MSI-8000 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/rice-lake/msi-8000/msi-8000_technical-manual_1453937017.webp)
Installation
© Rice Lake Weighing Systems
●
All Rights Reserved
13
2.5.3 PLC Wiring Diagrams
Pin # Wire Color
Function
Comment
1
Brown
Loop Voltage In
Optional for increasing compliance. Input range: +16V to 36Vmax
2
Black
Current Out
Will drive 20mA into 625Ω without external boost voltage. See
Table 2-3
.
3
White
Voltage Output
Specified for load resistance ≥1kΩ. Recommended load resistance: 100kΩ to minimize voltage drop due
to wire resistance in connecting cable.
4
Blue
Isolated Ground
Connection required for current and voltage output
Table 2-2. Analog Output Wiring
External Loop
Voltage Input
20mA Output Max R
wiring
+
R
shunt
24mA Output Max R
wiring
+
R
shunt
None
625Ω
520Ω
18V
750Ω
625Ω
24V
1.05kΩ
875Ω
30V
1.35kΩ
1.125kΩ
36V
1.65kΩ
1.375kΩ
Table 2-3. Current Compliance Table
16~36 Vdc
NC
NC
NC
Standard Current Output Wiring
P4-Isolated Gnd
P2-Current Out
P1-Loop Volt In
P3-Voltage Out
PLC
A/D
+
–
PLC
A/D
+
–
NC
NC
Voltage Output Wiring
PLC
A/D
+
–
Shunt
Shunt
See
Table
250Ω
Typ
Current Output Wiring with a Voltage Loop
P4-Isolated Gnd
P2-Current Out
P1-Loop Volt In
P3-Voltage Out
From
7001
or
7000
P4-Isolated Gnd
P2-Current Out
P1-Loop Volt In
P3-Voltage Out
From
7001
or
7000
From
7001
or
7000
Analog Output connector pin-out is pin
1=LOOPV IN, pin 2=VDAC OUT, pin 3=ISO
GND, and pin 4=IDAC OUT