![Rice Lake MSI-8000 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/rice-lake/msi-8000/msi-8000_technical-manual_1453937013.webp)
Introduction
© Rice Lake Weighing Systems
●
All Rights Reserved
9
1.9 MSI-7001HD Front Panel
Figure 1-4. MSI-7001HD Front Panel
Item No.
Description
1
Power In Connection – Located on the side of the unit
2
Power Button
Press & release – Turns unit on
Press & hold 1-4 seconds – Will auto zero
Press & hold 5 seconds – Turns unit off
3
Transmitter Power LED – Indicates state of unit power
Steady short green blinks – Good battery (or AC power)
Two red blinks then a pause – Low battery
Four red blinks then a pause – Very low battery
Steady red – Load cell fault (overload/underload/uncal/error/etc.)
Five green blinks per second – Calibration mode
Receiver Power LED – Indicates state of unit power
Steady short green blinks – RF connected, good battery (or AC power)
Two short red blinks then a pause – RF connected, low battery
Four short red blinks then a pause – RF connected, very low battery
Steady long red blinks – RF disconnected and good battery (or AC power)
Long red blink, short red blink then a pause – RF disconnected and low battery
Long red blink, three short red blinks – RF disconnected and very low battery
4
Communication Ports – Comm Port 1 is pre-set at 9600 baud and 8-N-1; Comm Port 2 is pre-set at 38400 baud and 8-N-1
5
Load Cell Connectors - Located on the side of the unit.
Table 1-6. MSI-7001HD Front Panel Controls
Blink Rate
1/s = Power OK
2/s = Low
4/s = Very Low
Red = LC Fault
5/s Green = Cal
POWER IN
POWER
1
2
COMM
PORTS
9600 Baud 8-N-1
CHANNEL
1
CHANNEL
2
MSI-7001HD
1
2
3
4
5
Содержание MSI-8000
Страница 49: ......