820i Programmable HMI Indicator/Controller
36
Visit our website
FEATURE Menu
Parameter
Choices
Description
Level 2 submenus
DATE
DATEFMT
DATESEP
Allows selection of date format and date separator character. See Level 3 submenu parameter descriptions.
Use the
TIME/DATE
softkey or the SD serial command to set the date. See
for infor
-
mation about using the serial commands.
TIME
TIMEFMT
TIMESEP
Allows selection of time format and separator character. See Level 3 submenu parameter descriptions.
Use the
TIME/DATE
softkey or the ST serial command to set the time. See
-
mation about using the serial commands.
DECFMT
DOT
COMMA
Specifies whether decimal numbers are displayed using a period (DOT) or comma as the decimal symbol.
DSPRATE
1
1–80
Display update rate. Specifies the display update rate, in the number of 100-millisecond intervals between
updates. The default value, 1, provides about 10 updates per second. The maximum value updates the dis
-
play every 8 seconds.
CONSNUM
0
0–9999999
Consecutive numbering. Allows sequential numbering for print operations. The consecutive number value is
incremented following each print operation that includes <CN> in the ticket format. When the consecutive
number is reset, it is reset to the value specified on the CONSTUP parameter.
CONSTUP
0
0–9999999
Specifies the consecutive number start-up value used when the consecutive number is reset by sending the
KCLRCN serial command or a CLRCN digital input. Value specified must be in the range 0–9 999 999.
UID
1
unit-ID
Specifies the unit identification number. Value specified can be any alphanumeric value, up to eight charac
-
ters.
TRUCK
OFF
MODE1
MODE2
MODE3
MODE4
MODE5
MODE6
Specifies the truck mode used. If selected, the indicator switches from normal mode to the selected truck
for more information about using the truck modes.
MODE1: Auto clear ID, keyed tares, value swapping
MODE2: Auto clear ID, no keyed tares, value swapping
MODE3: Stored ID, keyed tares, value swapping
MODE4: Stored ID, no keyed tares, value swapping
MODE5: Stored ID, keyed tares, no value swapping
MODE6: Stored ID, no keyed tares, no value swapping
ALIBI
OFF
ON
Specifies whether data storage is used by the alibi feature to allow reprinting any transaction.
Use the SOFTKEYS parameter to enable a softkey for recalling alibi print transactions.
CFGPWD
0
0–9999999
reset=999999
Configuration password. Specify a non-zero value to restrict access to all configuration menus.
NOTE: If a configuration password is specified, be sure to record the password and keep
it in a safe place. If the configuration password is lost or unavailable, the indicator must be
cleared (reset configuration and calibration parameters) to continue use.
To clear the indicator, press the setup switch, then enter 999999 (six nines) at the
configuration password prompt. The unit performs a RESETCONFIGURATION then
returns to the setup mode configuration display.
SPPWD
0
0–9999999
Setpoint password. Specify a non-zero value to restrict access to the setpoint menu.
The SPPWD is also shared by, and can be used to protect, the truck register. If a non-zero setpoint pass
-
word is specified, the password must be entered before deleting any entries from the truck register.
Table 3-7. FEATURE Menu Parameters