Setpoints
© Rice Lake Weighing Systems
●
All Rights Reserved
77
8.3 Batch Operations
Softkeys can be configured to allow operator control of batch operations from the
820i
front panel (see
), Softkeys
can be configured using
Revolution
, serial commands, or the FEATURE menu (see
).
Figure 8-10. Batching Softkeys
Setpoint
Display or change assigned setpoints.
Batch Start
Starts batch process.
Batch Pause
Pauses an active batch and turns off all digital outputs except those associated with concurrent and timer setpoints. Processing
is suspended until
Batch Start
is pressed again. Pressing
Batch Start
resumes the batch and re-energizes all digital outputs
turned off by the
Batch Pause.
Batch Reset
Stops and resets an active batch to the beginning of the process.
DURATION
hh:mm:ss
For TOD setpoints, specifies the length of time that the digital output associated with this setpoint
changes state. The value is entered in hours, minutes, and seconds
(hh:mm:ss).
All other operations
associated with this setpoint (print, tare, or accumulate) are performed at the end of the specified
duration.
NSAMPLE
1–65535
For AVG setpoints, specify the number of A/D samples used to calculate the average weight.
SOURCE
source_scale
Specify the scale number used as the source for the setpoint.
DIN SLOT
NONE
slot_number
For DIGIN and DINCNT setpoints, specify the slot number from which digital inputs will be read.
DIN MASK
digital_input_mask
For DIGIN and DINCNT setpoints, specify the bits used as inputs to the setpoint. Use the
Select
soft
-
key to select bits.
VUNDER
0–9999999
For CHKWEI setpoints, specifies the lower weight limit.
VOVER
0–9999999
For CHKWEI setpoints, specifies the upper weight limit.
DUNDER
digital_output
For CHKWEI setpoints, specifies the bit number of digital output activated when the scale weight is
less than the VUNDER value specified.
DACCEPT
digital_output
For CHKWEI setpoints, specifies the bit number of digital output activated when the scale weight
between the VUNDER and VOVER values specified.
DOVER
digital_output
For CHKWEI setpoints, specifies the bit number of digital output activated when the scale weight is
greater than the VOVER value specified.
COAST
0–65535
For PLSCNT setpoints, specifies the time delay (in 0.1-second intervals) inserted between reaching
the setpoint target value and capture of the actual pulse count.
SENSE
NORMAL
INVERT
Specifies whether the value of the digital output associated with this setpoint is inverted when the set
-
point is satisfied.
SETPTS Menu
Parameter
Choices
Description
Table 8-2. Setpoint Menu Parameters (Continued)
05/26/2006
11:08PM
2501
Scale
#1
lb
Gross
Setpoint
Batch Start Batch Pause Batch Reset Batch Stop