820i Programmable HMI Indicator/Controller
82
Visit our website
9.1.4 Parameter Setting Commands
Parameter setting commands allow you to display or change the current value for a particular configuration parameter (Tables
9-3 through 9-11).
Current configuration parameter settings can be displayed in either setup mode or normal mode using the following syntax:
command<ENTER>
Most parameter values can be changed in setup mode only; setpoint parameters listed in
can be changed
when in normal weighing mode.
Use the following command syntax when changing parameter values:
command=value<ENTER>
, where
value
is either a
number or a parameter value. Use no spaces before or after the equal (=) sign. If you type an incorrect command, the display
reads
??
.
For example, to set the motion band parameter on Scale #1 to 5 divisions, type the following:
SC.MOTBAND#1=5<ENTER>
For parameters with selectable values, enter the command and equal sign followed by a question mark:
command=?<ENTER>
to see a list of those values. The indicator must be in setup mode to use this function.
Some parameters are valid only if other parameters or parameter values are specified. See the configuration menus
in
for information about parameter dependencies. Restrictions for front-panel configuration also apply to
serial command configuration.
Command
Description
Values
SC.GRADS#
n
Graduations
1–9999999
SC.SPLIT#
n
Multi-range or multi-interval scale type
OFF, 2RNG, 3RNG, 2INTVL, 3INTVL
SC.ZTRKBND#
n
Zero track band
0,
0–100
SC.ZRANGE#
n
Zero range
1.900000,
0–100
SC.MOTBAND#
n
Motion band
1,
0–100
SC.SSTIME#
n
Standstill time
1–65535
SC.OVRLOAD#
n
Overload
FS+2%, FS+1D, FS+9D, FS
SC.WMTTHRH#
n
Weighment threshold
grads
SC.NUMWEIGH#
n
Number of weighments
—
SC.MAX_WEIGHT#
n
Maximum weight
—
SC.DIGFLTR1#
n
SC.DIGFLTR2#
n
SC.DIGFLTR3#
n
Digital filtering
1, 2, 4, 8, 16, 32, 64, 128, 256
SC.DFSENS#
n
Digital filter cutout sensitivity
2OUT, 4OUT, 8OUT, 16OUT, 32OUT, 64OUT, 128OUT
SC.DFTHRH#
n
Digital filter cutout threshold
NONE, 2D, 5D, 10D, 20D, 50D, 100D, 200D, 250D
SC.RATLTRAP#
n
Rattletrap filtering
OFF, ON
SC.SMPRAT#
n
Sample rate
30HZ, 60HZ, 120HZ, 240HZ, 480HZ, 960HZ
SC.PWRUPMD#
n
Power up mode
GO, DELAY
SC.TAREFN#
n
Tare function
BOTH, NOTARE, PBTARE, KEYED
SC.PRI.DECPNT#
n
Primary units decimal position
8.888888, 88.88888, 888.8888, 8888.888, 88888.88, 888888.8,
8888888, 8888880, 8888800
SC.PRI.DSPDIV#
n
Primary units display divisions
1D, 2D, 5D
SC.PRI.UNITS#
n
Primary units
lb, kg, g, oz, tn, t, gn, troyoz, troylb, lt, CUSTOM, NONE, OFF
SC.PRI.CUNITS#
n
Primary custom units
Specify units if SC.PRI.UNITS=CUSTOM
SC.SEC.DECPNT#
n
Secondary units decimal position
8.888888, 88.88888, 888.8888, 8888.888, 88888.88, 888888.8,
8888888, 8888880, 8888800
SC.SEC.DSPDIV#
n
Secondary units display divisions
1D, 2D, 5D
Table 9-3. SCALES Serial Commands
Note