820i Programmable HMI Indicator/Controller
86
Visit our website
CONTACT.EMAIL
Contact e-mail address
contact_e-mail_address
(up to 30 characters)
NEXTCAL
Next calibration date
calibration_date
GRAVADJ
Gravitational adjustment
OFF, ON
LAT.LOC
Latitude
0–90
(to nearest degree of latitude)
ELEV.LOC
Elevation
±0–9999
(in meters)
IMAGE
Display image
NEGATIVE, POSITIVE
Command
Description
Values
SP.KIND#
n
Setpoint kind
OFF,
GROSS, NET, –GROSS, –NET, ACCUM, ROC, +REL, –REL, %REL, RES
-
REL, PAUSE, DELAY, WAITSS, COUNTER, AUTOJOG, COZ, INMOTON,
INRANGE, BATCHPR, TIMER, CONCUR, DIGIN, AVG, TOD, DELTA, CHWEI,
PLSCNT, PLSRAT, ALWAYS, NEVER, DINCNT
SP.VALUE#
n
Setpoint value
number
SP.SOURCE#
n
Source scale
SCALE1, SCALE2, SCALE3
SP.COAST#
n
Pulse counter coast
number
SP.TRIP#
n
Trip
HIGHER, LOWER, INBAND, OUTBAND
SP.BANDVAL#
n
Band value
number
SP.HYSTER#
n
Hysteresis
number
SP.PREACT#
n
Preact type
OFF, ON, LEARN, FLOW
SP.PREVAL#
n
Preact value
number
SP.PREADJ#
n
Preact adjustment percentage
number
SP.PRESTAB#
n
Preact learn stability
number
SP.PCOUNT#
n
Preact learn interval
number
SP.TOLBAND#
n
Target tolerance
number
SP.TOLCNT#
n
Tolerance count
number
SP.BATCH#
n
Batch step enable
OFF, ON
SP.CLRACCM#
n
Clear accumulator enable
OFF, ON
SP.CLRTARE#
n
Clear tare enable
OFF, ON
SP.PSHACCM#
n
Push accumulate
OFF, ON, ONQUIET
SP.PSHPRINT#
n
Push print
OFF, ON, WAITSS
SP.PSHTARE#
n
Push tare
OFF, ON
SP.ALARM#
n
Alarm enable
OFF, ON
SP.NAME#
n
Setpoint name number
NONE,
1–60
SP.ACCESS#
n
Setpoint access
OFF, ON, HIDE
SP.DSLOT#
n
Digital output slot
NONE, SLOT
x
SP.DIGOUT#
n
Digital output
BIT
x
SP.SENSE#
n
Digital output sense
NORMAL, INVERT
SP.BRANCH#
n
Branch destination
0,
1-100
SP.RELNUM#
n
Relative setpoint number
1–100
SP.START#
n
Starting setpoint
1–100
SP.END#
n
Ending setpoint
1–100
SP.DISLOT#
n
Digital input slot
NONE, SLOT
x
Table 9-6. SETPNTS Serial Commands
Command
Description
Values
Table 9-5. FEATURE Serial Commands (Continued)
Содержание 820i
Страница 115: ......