Serial Commands
© Rice Lake Weighing Systems
●
All Rights Reserved
89
9.1.5 Normal Mode Commands
The normal mode print commands (see Table 9-11) transmit data to the serial port on demand in either setup or normal mode.
9.1.6 Batching Control Commands
The commands listed in Table 9-12 provide batching control through the serial port
Command
Description
Values
CONSNUM
Set consecutive number
0–9 999 999
UID
Set unit ID
nnnnnnn
SD
Set date
MMDDYY
,
DDMMYY, YYMMDD,
or
YYDDMM
.
Enter six-digit date using
the year-month-day order specified for the DATEFMT parameter, using only the last
two digits of the year.
ST
Set time
hhmm
(enter using 24-hour format)
CONTRAST
Set display contrast
0–127
BACKLITE
Set display backlighting
ON, OFF
SX#
n
Start serial port streaming
OK
or
??
The port streaming parameter (EDP.STREAM#
p
) for the streaming port must be set
to LFT or INDUST before using these commands.
An EX command sent while in setup mode does not take effect until the indicator is
returned to normal mode.
EX#
n
Stop serial port streaming
SF#
n
Transmit single frame of stream
Sends a single frame from scale
n
to the streaming port
RS
Reset system
Soft reset. Used to reset the indicator without resetting the configuration to the factory
defaults.
XA#
n
Transmit accumulator value in displayed units
nnnnnn UU
XAP#
n
Transmit accumulator value in primary units
XAS#
n
Transmit accumulator value in secondary units
XAT#
n
Transmit accumulator value in tertiary units
XG#
n
Transmit gross weight in displayed units
nnnnnn UU
XGP#
n
Transmit gross weight in primary units
XGS#
n
Transmit gross weight in secondary units
XGT#
n
Transmit gross weight in tertiary units
XN#
n
Transmit net weight in displayed units
nnnnnn UU
XNP#
n
Transmit net weight in primary units
XNS#
n
Transmit net weight in secondary units
XNT#
n
Transmit net weight in tertiary units
XT#
n
Transmit tare weight in displayed units
nnnnnn UU
XTP#
n
Transmit tare weight in primary units
XTS#
n
Transmit tare weight in secondary units
XTT#
n
Transmit tare weight in tertiary units
XE
Query system error conditions
nnnnn
See
for detailed information about the XE command
response format.
Table 9-11. Normal Mode Serial Commands
Command
Description
Values
BATSTART
Batch start
If the BATRUN digital input is active (low) or not assigned, the BATSTART command can be used to start the batch
program.
BATSTOP
Batch stop
Stops the batch program and turns off all associated digital outputs.
BATPAUSE
Batch pause
Stops the batch program at the current step. All digital outputs set on by the current step (except for those set by con
-
cur setpoints) are set off. The BATSTRT DIGIN, BATSTART serial command,
Batch Start
softkey, or the StartBatch
function in an
iRite-IDE
program can be used to restart the batch program at the current step.
BATRESET
Batch reset
Stops the program and resets the batch program to the first batch step. Run the BATRESET command after making
changes to the batch configuration.
Table 9-12. Batching Control Commands