820i Programmable HMI Indicator/Controller
76
Visit our website
RELNUM
1
1–100
For relative setpoints, specifies the number of the relative setpoint. The target weight for this setpoint
is determined as follows:
• For +REL setpoints, the value of the relative setpoint plus the value (VALUE parameter) of the +REL
setpoint
• For –REL setpoints, the value of the relative setpoint minus the value of the –REL setpoint
• For %REL setpoints, the percentage (specified on the VALUE parameter of the %REL setpoint) of
the target value of the relative setpoint
• For RESREL setpoints, the percentage (specified on the VALUE parameter of the RESREL setpoint)
of the
captured
value of the relative setpoint
BATCH
OFF
ON
Specifies whether the setpoint is used as a batch (ON) or continuous (OFF) setpoint.
CLRACCM
OFF
ON
Specify ON to clear the accumulator when the setpoint is satisfied
CLRTARE
OFF
ON
Specify ON to clear the tare when the setpoint is satisfied
PSHACCM
OFF
ON
ONQUIET
Specify ON to update the accumulator and perform a print operation when the setpoint is satisfied.
Specify ONQUIET to update the accumulator without printing.
PSHPRNT
OFF
ON
WAITSS
Specify ON to perform a print operation when the setpoint is satisfied; specify WAITSS to wait for
standstill after setpoint is satisfied before printing.
PSHTARE
OFF
ON
Specify ON to perform an acquire tare operation when the setpoint is satisfied.
NOTE: PSHTARE acquires the tare regardless of the value specified for the
REGULAT parameter on the FEATURE menu.
NOTE: If two or more of the CLRxxxx and PSHxxxx parameters are set on, the actions specified by those parameters are
performed in the following order when the setpoint is satisfied: 1) clear accumulator; 2) clear tare; 3) accumulate; 4) print; 5)
acquire tare.
ALARM
OFF
ON
Specify ON to display the word
ALARM
on the primary display while the setpoint is active (batch set
-
points) or while the setpoint is not tripped (continuous setpoints).
START
1
1–100
Specifies the starting setpoint number.
Do not
specify the number of the TIMER or CONCUR setpoint
itself. The TIMER or CONCUR setpoint begins when the starting setpoint begins.
END
1
1–100
Specifies the ending setpoint number.
Do not
specify the number of the TIMER or CONCUR setpoint
itself. The TIMER or CONCUR setpoint stops when the ending setpoint begins.
ACCESS
ON
HIDE
OFF
Specifies the access allowed to setpoint parameters shown by pressing the
Setpoint
softkey in nor
-
mal mode.
ON: Values can be displayed and changed
HIDE: Values cannot be displayed or changed
OFF: Values can be displayed but not changed
NAME
NONE, 1–60
Specify the number of an assigned prompt. Up to 60 prompt names can be specified on the
PROMPTS submenu of the FEATURE menu.
SLOT
NONE
slot_number
Lists all available digital I/O slots. This parameter specifies the slot number of the digital I/O card ref
-
erenced by the DIGOUT parameter.
DIGOUT
bit_number
Lists all digital output bits available for the specified SLOT. This parameter is used to specify the digi
-
tal output bit associated with this setpoint. Use the DIG I/O menu to assign bit function to OUTPUT.
For continuous setpoints, the digital output becomes active (low) when the condition is met; for batch
setpoints, the digital output is active
until
the setpoint condition is met.
BRANCH
0
1-100
Specifies the setpoint number to which the batch sequence is to branch if the current setpoint is not
satisfied upon initial evaluation.
The special value zero indicates that no branch is taken.
TIME
time
For TOD setpoints, specifies the time at which the setpoint becomes active. The format used to enter
the time (12-hour or 24-hour) is based on the value specified for the TIMEFMT parameter on the FEA
-
TURE menu.
SETPTS Menu
Parameter
Choices
Description
Table 8-2. Setpoint Menu Parameters (Continued)