4-96
ECODRIVE03 DKC**.040, DKC**.100, DKC**.200
ECODRIVE03 Drive Controllers
XS1, XS2, XS3 Shield Connections
XS1
Connection for shield:
•
Total motor cable shield
•
Holding brake
•
Motor temperature monitoring
•
Mains supply
XS2
Connection for shields of cables at X1, X3 and those for the command
communication interfaces.
XS3
Connection for shields of cables at X9, X10 and X11.
Drive controller
XS1
XS2
XS3
DKC**.3-040
12-18
6-15
6-15
DKC**.3-100
12-35
6-15
6-15
DKC**.3-200
19-35
6-15
6-15
Fig. 4-158: Allowed outside diameters in mm
Note:
Always connect the shield connections of the cables
(especially of the motor cables) with a large contact surface.
Allowed outside diameters:
|