ECODRIVE03 Drive Controllers
ECODRIVE03 Auxiliary Capacitance Module CZM01.3
7-7
Ap5137f1.fh7
CZM1.3
DKC**.3
K1
3
3
-040
-100
-200
Fig. 7-13:
Connection of auxiliary capacitance module CZM01.3
CAUTION
Damage possible if DC bus connections L+ and
L- are reversed!
Make sure polarity is correct.
If the DC bus rails supplied do not make a connection possible, then use
short twisted wires to do so.
wire length:
max. 2 x 1 m
wire cross section:
min. 10 mm ²,
not smaller than the cross
section of the mains supply
lead
wire protection
with a fuse in the mains
connections
voltage resistance of individual wires to
ground
> 750V
(e.g., litz wires - H07)
Wire
DC bus:
|