![Rexroth Indramat BZM 01.3-01-07 Скачать руководство пользователя страница 94](http://html1.mh-extra.com/html/rexroth-indramat/bzm-01-3-01-07/bzm-01-3-01-07_project-planning-manual_1449634094.webp)
4-62
ECODRIVE03 DKC**.040, DKC**.100, DKC**.200
ECODRIVE03 Drive Controllers
X5, DC bus, Motor and Mains Connections
Technical description of connector
Ap5267f1.FH7
L+
L-
L1
L2
L3
A1
A2
A3
Fig. 4-89:
Connector X5
Type
No. of pins
Design
connection block
2 / 3 / 3
screw-in connection for
ring terminals M5
Fig. 4-90:
Design
min. tightening torque
[Nm]
max. tightening torque
[Nm]
0
.
3
5
.
2
Fig. 4-91: Tightening torque
Cross section
single wire
[mm ²]
max. connectable
cross section
[mm ²]
max. Cross section
in AWG
gauge no.:
-
-
5
2
-
-
Fig. 4-92:
Connection cross section
DC bus connection
The DC bus connection connects several controllers to each other plus it
connects controllers together with auxiliary components
•
Increase allowed DC bus continuous power
•
Increase allowed bleeder continuous load
•
Allow connections for "Central supply"
device-external
device-internal
AP5301F1.FH7
X5
L+
L-
DC bus connection
Fig. 4-93:
DC bus connection
Illustration:
Design:
Tightening torque:
Connection cross section:
Connection
DC bus:
|
(479) 422-0390