4-4
ECODRIVE03 DKC**.040, DKC**.100, DKC**.200
ECODRIVE03 Drive Controllers
Ambient and operating conditions
Note:
ECODRIVE03 drive control devices and its auxiliary
components are designed for control cabinet mounting.
Selection lists are specified for each motor/drive combination.
The selection lists apply to motors and drives within the specified ambient
and operating conditions (see "Fig. 4-5: Ambient
and
operating
conditions").
Differing conditions reduce the performance specifications
•
of the drive:
•
allowed DC bus continuous output
•
continuous bleeder output
•
continuous current
•
of the motor:
•
output
•
continuous torque at standstill
•
S1 continuous torque
•
Short-time operating torque
M
KB
according to the diagrams (see "Fig. 4-4:
Degree of utilization as a
value dependent on ambient temperature and installation altitude"). If
deviating ambient temperatures and higher installation altitudes occur
simultaneously, both utilization factors must be multiplied. The installation
altitude must only be taken into account once. Deviating ambient
temperatures must be taken into account separately for motor and drive
controller.
DG5025F1.FH7
Load capacity dependent on
ambient temperature
Load capacity dependent on
installation elevation
Load factor f
T
Load factor f
H
Ambient temperature in °C
Installation elevation in meters
above sea level
500
1000
1500 2000
0,6
0,8
1
0,6
0,8
1
40
45
50
55
0
Fig. 4-4:
Degree of utilization as a value dependent on ambient temperature
and installation altitude
Ambient temperature and
installation altitude
|
(479) 422-0390