ECODRIVE03 Drive Controllers
ECODRIVE03 DKC**.040, DKC**.100, DKC**.200
4-63
CAUTION
Damage possible if DC bus connections L+ and
L- are reversed!
Make sure polarity is correct.
If the DC bus rails supplied do not make a connection possible, then use
short twisted wires to do so.
wire length:
max. 2 x 1 m
wire cross section:
min. 10 mm ²,
not smaller than the cross
section of the mains supply
lead
wire protection
With a fuse in the mains
connections
Voltage resistance of individual wires
to ground
> 750 V
(e.g., litz wires - H07)
wire
DC bus:
|
(479) 422-0390