16.6 Command Value Box Connection
To run the drive, a command value must be set at the relevant interface
(positioning, analog or step motor interface).
For test purposes, a velocity command value can be set with the help of a
command value box via the analog interface.
The following illustrates a command value box circuit recommendation.
12
10k
V
13k
DC (-10...+10)V
+15 V
-15 V
analog E1+
1
2
3
4
24V
RF
0VM
AP5096F1.FH7
X3
X1
DKC
Command value box
Reverse direction
command value
13
14
15
analog E1-
analog E2+
analog E2-
Analog
command
value
input
AH/Start
Drive enable
Drive stop/start
DC24V of
control volt.
Fig. 16-37: Command value box circuit recommendation for connecting an
analog interface
Note:
The analog input (not present on DKC**.3-016) used has to be
parameterized.
See firmware functional description.
Command Value Box
|