18. Error code table
ERROR
WHAT HAPPENED
WHAT TO DO
Err 10
The water reaches the max level but
does not reach the min level in two
minutes.
Error message can be cancelled by pressing the “
ESC
”
button. Combi oven can be used in “
Hot air
” only.
Please call your service company.
Err 11
Preheating of a boiler took longer than
6 min.
Error message can be cancelled by pressing the “
ESC
”
button. Combi oven can be used in “
Hot air
” only.
Please call your service company.
Err 12
When filling the boiler, the max water
level is not reached in 2 minutes.
Error message can be cancelled by pressing the “
ESC
”
button. Combi oven can be used in “
Hot air
” only.
Please call your service company.
Err 13
When filling the boiler, the min water
level is not reached in 2 minutes.
Check water supply line (open valve)
Error message can be cancelled by pressing the “
ESC
”
button. Combi oven can be used in “
Hot air
” only.
Please call your service company.
Err 14
One phase of a power distribution is
missing
Please call your service company.
Err 15
F2 motor thermal overload protection
failure. Indication of motor overheating
above a set limit.
Please call your service company.
Err 16
Preheating of a boiler took longer than
7 min.
Error message can be cancelled by pressing the “
ESC
”
button. Combi oven can be used in “
Hot air
” only.
Please call your service company.
Err 17
When emptying the boiler, the water
level did not decrease under the min
level in 2min.
Error message can be cancelled by pressing the “
ESC
”
button. Combi oven can be used in “
Hot air
” only.
Please call your service company.
Err 18
When emptying the boiler, the water
level did not decrease under the max
level in 2min.
Check the drain.
Error message can be cancelled by pressing the “
ESC
”
button. Combi oven can be used in “
Hot air
” only.
Please call your service company.
Err 19
Calcified boiler
Please call your service company.
Err 26
Flap valve motor is not blocked or
switch is still closed.
Error message can be cancelled by pressing the “
ESC
”
button. Combi oven can be used without the “
Flap
valve
” function.
Err 27
Flap valve motor is not blocked or
switch is still opened.
Error message can be cancelled by pressing the “
ESC
”
button. Combi oven can be used without the “
Flap
valve
” function.
Err 28
Flap valve switch failure.
Error message can be cancelled by pressing the “
ESC
”
button. Combi oven can be used without the “Flap
valve” function.
Err 29
Flap valve motor failure.
Error message can be cancelled by pressing the “
ESC
”
button. Combi oven can be used without the “Flap
valve” function.
Содержание vision
Страница 1: ...T o u c h t h e f u t u r e ...
Страница 62: ...OPERATING MANUAL FOR RETIGO BLUE VISION COMBI STEAMERS 62 ver EN04 06 12 NOTES ...
Страница 63: ...OPERATING MANUAL FOR RETIGO BLUE VISION COMBI STEAMERS 63 ver EN04 06 12 NOTES ...
Страница 64: ...OPERATING MANUAL FOR RETIGO BLUE VISION COMBI STEAMERS 64 ver EN04 06 12 NOTES ...
Страница 65: ...OPERATING MANUAL FOR RETIGO BLUE VISION COMBI STEAMERS 65 ver EN04 06 12 NOTES ...