OPERATING MANUAL FOR
RETIGO BLUE VISION
COMBI STEAMERS
58
ver. EN04/06/12
Regular air filter cleaning and following the
maintenance instructions helps to significantly prolong
the lifetime of the device and guarantees its trouble-free
operation.
16.5 Annual maintenance
•
Carry out the quarterly maintenance.
•
It is also necessary to check the installation and
equipment. RETIGO s.r.o. recommends to
carrying out this procedure only through an
authorised service.
•
Only expert installation and compliance with the
maintenance instructions increases the lifecycle
of the device and guarantees its trouble-free
operation.
•
After one year of operation an authorised service
should check the installation and the device
according to the check list.
•
For the entire duration of operation, the device
must undergo regular checks, tests and revisions
as required by ČÚBP no. 48/1982 Codex.
•
The warranty does not cover damage caused by
unprofessional cleaning and maintenance.
•
The user of the device must not alter the values
preset by the manufacturer or assigned service
technician.
•
Only through regular checks and cleaning of the
device can you avoid excessive wear and tear to
the device.
Exhaust flue inspection
(valid for gas combi steamers only)
If the combi steamer is of type B, regular service,
maintenance and exhaust flue sweeping must be
carried out at least once a year (Czech Norm - ČSN EN
73 4201/2008), if the relevant national regulations do
not set shorter interval (e.g., still valid regulation Nr.
111/1981 Coll., which sets a six-month interval).
CHECK LIST
1
Following the encloses installation instructions
2
Levelling the device into a horizontal position
3
Adjustment of the door
4
Connection of appliance to cold water
5
Setting the pressure of inflowing water to
300 – 500 kPa
6
Complying to inclination, min. length and
diameter of drain pipe
7
Minimum distance of 50 cm from other heat
sources
8
Minimum distance of 5 cm from other terminal
surfaces
9
Space for the free air flow of at least 50 cm
above the device
10
Sufficient working area for operation and
maintenance
11
Water softener if water hardness exceeds
10_N
12
Electric fuse protection of the device
13
Compliance with fire regulations
14
Electric fuse protection of the device
15
Call customer’s attention to the conditions
for cleaning and maintenance of the device
16
Call customer’s attention to the principles
of decalcifying the boiler
Содержание vision
Страница 1: ...T o u c h t h e f u t u r e ...
Страница 62: ...OPERATING MANUAL FOR RETIGO BLUE VISION COMBI STEAMERS 62 ver EN04 06 12 NOTES ...
Страница 63: ...OPERATING MANUAL FOR RETIGO BLUE VISION COMBI STEAMERS 63 ver EN04 06 12 NOTES ...
Страница 64: ...OPERATING MANUAL FOR RETIGO BLUE VISION COMBI STEAMERS 64 ver EN04 06 12 NOTES ...
Страница 65: ...OPERATING MANUAL FOR RETIGO BLUE VISION COMBI STEAMERS 65 ver EN04 06 12 NOTES ...