PART V APPENDIX - CHANGES OF THE UNIT
E-53
ENGLISH
Serial number
R3000001A ~
R3000350A
Features and changes
2 RESET buttons
1. Press the RESET 1
button 5 times to reset the
timer for FILTER LIFE.
2. Press the RESET 2
button 5 times to reset UV
LAMP.
NEG. ION
M
H
L
CHECK
FILTER LIFE
3h
1h
POWER
SPEED
TIMER
UV LAMP
2h
AUTO
ON
TIMER Button
Press the TIMER button to select the
time for operation. Each time it is
pressed the timer setting switches as
shown below:
1hr-2hr-3hr
Cancel
R3000351B ~
R3000680B
Added a reset button on the back of the unit.
1. Press the button one time to reset FILTER LIFE.
2. Hold the button 5 seconds to reset the UV LAMP.
1. Cancelled the reset button on the back of the unit.
2. Added a function of the POWER button as a reset
button. Holding the POWER button 3 seconds will reset
CARBON FILTER, UV LAMP or CLEAN CELL indicator
light.
A
B
R3000681C ~
R3001020C
C
POWER
RESET
SPEED
UV LAMP
AUTO
NIGHT
NEG. ION
TIMER
One reset button on the
remote control:
Press the reset button 3-5
times to reset CARBON
FILTER, UV LAMP and
CLEAN CELL indicator
light.
NEG. ION
M
H
L
CHECK
CARBON FILTER
12h
4h
POWER
SPEED
TIMER
UV LAMP
8h
AUTO
ON
/
CLEAN CELL
Timer changes:
The timer is changed from 1h-2h-3h to 4h-
8h-12h.
Indicator light changes:
Added the CLEAN CELL indicator light.