PART IV
TROUBLESHOOTING -ELECTRICAL SHOCK
E-52
Adjust Pre filter ground clip so that it can contact the Pre filter and cell clips correctly.
2. Check cell ground contact plate
A. Open the bottom plate.
B. Visually check if the unit ground contact plate is deformed causing the cell can not contact the ground contact
plate. If not, you have to adjust contact plate or change the power contact board.
Adjust cell ground contact plate so that
it can contact the cell closely.
1. Check Pre filter and cell ground clips
A. Stop the unit and unplug the power cord.
B. Open the front panel and pull out the Pre filter and cell.
C. Visually check if the Pre filter ground and cell clips are pressed down.
Repair tips:
1. Check Pre filter and cell ground clips
2. Check cell ground contact plate
Electrical shock occurs when touching the front panel.
ENGLISH
ELECTRICAL SHOCK