PART IV
TROUBLESHOOTING - UNIT RESET
E-45
When the CARBON FILTER (FILTER LIFE) or UV LAMP indicator light flashes you need to replace them. After replacing the activated
carbon filter or UV lamp, you need to reset the timer. When the CELL CLEANING indicator light flashes, you also need to reset after
cleaning the cell.
Check remote control
1. Check if other buttons of the remote control work correctly.
2. If all the buttons do not work, check the battery of the remote control.
3. If the battery is OK, try to change a new remote control to reset the unit.
4. If all the remote controls do not work, go ahead to check the remote signal receiver on the display circuit board.
5. If the new remote signal receiver still does not work, you will need to check the display circuit board wire or replace the main circuit
board.
1. When the CARBON FILTER indicator light flashes,
you need to change the activated carbon filter and
press the RESET 1 button on the remote control 5
times to reset.
2. When the UV LAMP indicator light flashes, you
need to change the UV lamp and press the RESET 2
button on the remote control 5 times to reset.
You can see a light under the cell
phone camera mode if the remote
control is OK.
ENGLISH
Press the RESET 1 button 5 times
to reset the timer for activated
carbon filter: 1, 2, 3, 4, 5-beep~
Press the RESET 2 button 5
times to reset the timer for UV
lamp: 1, 2, 3, 4, 5-beep~
1. A simple way to check if the remote control: Press any
button on the remote control under the camera or video mode
under the cell phone. You can see a light if the remote control
is OK.
2. Most of the problem is due to remote control. It will rarely
happen that the remote signal receiver board, display circuit
board wire or main circuit board will be broken.
Check remote control
Step 1
Helpful hints