Interface Specification Document
6.3.1.13 Dot Check (bathy only)
•
DESCRIPTION:
This message controls the bottom detection dots on the sonar screen.
•
SYNTAX:
*DCHK,N<CR><LF>
•
PARAMETERS:
N – Dots selection.
0 – Off. (No dots.)
1 – Normal. (Displays all dots except those of poor quality.)
2 – All. (Displays all dots in white, even the quality dots.)
3 – Quality. (Displays all dots, color-coded with quality.)
4 – Process. (Displays all dots, color-coded depending on the bottom detection
algorithm.)
•
EXAMPLE:
*DCHK,0<CR><LF>
This example turns the dots Off.
6.3.1.14 Maximum Depth Filter (bathy only)
•
DESCRIPTION:
This message sets the maximum value for the depth filter.
•
SYNTAX:
*DMAX,N<CR><LF>
•
PARAMETERS:
N – Max depth filter [m]. The parameter go from 0 m to max range, but higher or equal
than to the minimum depth filter settings.
•
EXAMPLE:
*DMAX,100<CR><LF>
This example sets the maximum depth filter value to 100 m.
6.3.1.15 Minimum Depth Filter (bathy only)
•
DESCRIPTION:
This message sets the minimum value for the depth filter.
•
SYNTAX:
*DMIN,N<CR><LF>
•
PARAMETERS:
N – Min depth filter [m]. The parameter go from 0 m to max range, but less or equal to the
maximum depth filter setting.
•
EXAMPLE:
*DMIN,10<CR><LF>
This example sets the minimum depth filter value to 10 m.
______________________________________________________________________
SeaBat 8101 Operator's Manual
6-10
(ISD Rev 1.23) Version 3.02