Interface Specification Document
6.2.1.5 Ethernet
Select either 10 Base T (RJ45 connector) or 10 Base 2 (BNC connector) for network communica-
tion.
•
10 Base T – Use an Unshielded Twisted Pair Category 5 Cable, no more than 100 m in
length, with an RJ45 connector. When connecting the processor unit directly to a PC use a
cross over cable. Use a straight through cable when connecting to a HUB. To create a
Straight-Through or a Cross-Over Cable use drawings below:
STRAIGHT-THROUGH
Connector 1
Pin
Connector 2
White/Orange 1
White/Orange
Orange 2
Orange
White/Green 3
White/Green
Blue 4
Blue
White/Blue 5
White/Blue
Green 6
Green
White/Brown 7
White/Brown
Brown 8
Brown
The Cross-Over wires differ from the Straight-Through according to the following picture / table:
CROSS-OVER
Connector 1
Pin
Connector 2
White/Orange 1
White/Green
Orange 2
Green
White/Green 3
White/Orange
Blue 4
Blue
White/Blue 5
White/Blue
Green 6
Orange
White/Brown 7
White/Brown
Brown 8
Brown
______________________________________________________________________
SeaBat 8101 Operator's Manual
6-4
(ISD Rev 1.23) Version 3.02