4 . 0 U S E R I N T E R F A C E
Programming Card
Channel Compatibility
Minimum Flash
Minimum Yellow
Clearance Disable
CVM Latch
24V Monitor Latch
Integral EEPROM
Reset Button
Press to attempt to
clear Faults
Turns on all LEDs for
300 msec.
Comm Port
RS-232 Port for
communications
Port 1 SDLC
SDLC Port for
communications with
the Controller
Field Status
1 LED for each field
input
All field status LEDs
are latched if a fault
occurs
Field inputs that
caused the fault will
flash when the fault is
displayed
Power LED
ON = AC power OK
Flashing = AC power
is low
Type 12 LED
ON = Type 12 Mode
OFF = Type 16 Mode
Blip = Type 16 Only
Receive & Transmit
Receive ON = A valid
SDLC frame
addressed to the
monitor was received
Transmit ON = A
SDLC frame was
transmitted
Fault LEDs
ON = Fault
Blip = Fault Disabled
Fuse
1/4 Amp Slo-Blo
Connector B
Channel Red Inputs
Red Enable
Start Delay Relay
Local Flash
+24V Monitor II
Connector A
Channel Green,
Yellow, and Walk
Inputs
Output Relay
CVM
+24V Monitor I
+24V Monitor Inhibit
Cabinet Interlock
Type Select
Help Button
Press to access
content sensitive
Help Mode
OLED Display Screen
Displays monitor
status and is used to
select options and
configure monitor
settings
Programming Buttons
UP, DOWN, LEFT,
RIGHT, ENTER, and
ESCAPE pushbuttons
are used to program
monitor
Ethernet Connector
Optional RJ-45
Interface connector
for network
communications