Rev. 2.0, 11/00, page 761 of 1037
VISS Detect Mode and VASS Detect Mode:
The duty I/O flag indicates the result of duty discrimination. The duty I/O flag is 1 when the duty
cycle of the PB-CTL signal is equal to or above 44% (a 0 pulse in the CTL signal). The duty I/O flag
is 0 when the duty cycle of the PB-CTL signal is below 43% (a 1 pulse in the CTL signal).
ASM Mark Detect Mode:
The duty I/O flag indicates the result of duty discrimination. The duty I/O flag is 0 when the
duty cycle of the PB-CTL signal is equal to or above 66% (when an ASM mark is detected).
The duty I/O flag is 1 when the duty cycle of the PB-CTL signal is below 65% (when an ASM
mark is not detected).
VISS Record Mode and VISS Rewrite Mode:
The duty I/O flag operates according to a control signal from the VISS control circuit, and
controls the write control circuit so as to write an index code. The write timing is set in the
REC-CTL duty data registers (RCDR1 to RCDR5). For VISS recording, registers RCDR1 to
RCDR5 are set with reference to REF30X. For VISS rewrite, registers RCDR2 to RCDR5 are
set with reference to the low-to-high transition of the previously recorded CTL signal, and the
write is carried out through the trapezoid waveform generator.
Set the duty timing for a 1 pulse (short) in RCDR2, for a 1 pulse (long) in RCDR3, for a 0 pulse
(short) in RCDR4, and for a 0 pulse (long) in RCDR5.
While an index code is being written, the value of the bit being written can be read by reading
the duty I/O flag. If the CTL signal currently being written is a 0 pulse, the duty I/O flag will
read 1. If the CTL signal currently being written is a 1 pulse, the duty I/O flag will read 0.
VASS Record Mode and VASS Rewrite Mode:
The duty I/O flag is used for write control, one CTL pulse at a time. The write timing is set in
the REC-CTL duty data registers (RCDR1 to RCDR5). For VASS recording, registers RCDR1
to RCDR5 are set with reference to REF30X. For VASS rewrite, registers RCDR2 to RCDR5
are set with reference to the low-to-high transition of the previously recorded CTL signal, and
the write is carried out through the trapezoid waveform generator.
Set the duty timing for a 1 pulse (short) in RCDR2, for a 1 pulse (long) in RCDR3, for a 0 pulse
(short) in RCDR4, and for a 0 pulse (long) in RCDR5.
If 0 is written in the duty I/O flag, a CTL pulse will be written with a duty cycle set in RCDR2
and RCDR3, referenced to the immediately following REF30X. If 1 is written in the duty I/O
flag, a CTL pulse will be written with a duty cycle set in RCDR4 and RCDR5, referenced to the
immediately following REF30X.
ASM Record Mode:
The duty I/O flag is used for write control, one CTL pulse at a time. The write timing is set in
the REC-CTL duty data registers (RCDR1 and RCDR3). If 0 is written in the duty I/O flag, a
CTL pulse will be written with a duty cycle of 67% to 70% as set in RCDR3, referenced to the
immediately following REF30X.
Содержание Hitachi H8S/2191
Страница 123: ...Rev 2 0 11 00 page 96 of 1037...
Страница 149: ...Rev 2 0 11 00 page 122 of 1037...
Страница 197: ...Rev 2 0 11 00 page 170 of 1037...
Страница 247: ...Rev 2 0 11 00 page 220 of 1037...
Страница 249: ...Rev 2 0 11 00 page 222 of 1037...
Страница 347: ...Rev 2 0 11 00 page 320 of 1037...
Страница 357: ...Rev 2 0 11 00 page 330 of 1037...
Страница 417: ...Rev 2 0 11 00 page 390 of 1037...
Страница 431: ...Rev 2 0 11 00 page 404 of 1037...
Страница 439: ...Rev 2 0 11 00 page 412 of 1037...
Страница 457: ...Rev 2 0 11 00 page 430 of 1037...
Страница 525: ...Rev 2 0 11 00 page 498 of 1037...
Страница 543: ...Rev 2 0 11 00 page 516 of 1037...
Страница 639: ...Rev 2 0 11 00 page 612 of 1037 28 1 2 Block Diagram Figure 28 1 shows a block diagram of the servo circuits...
Страница 845: ...Rev 2 0 11 00 page 818 of 1037...