Section 6 ROM
Rev. 6.00 Aug 04, 2006 page 186 of 680
REJ09B0145-0600
6.9
Program/Erase Protection
There are three kinds of flash memory program/erase protection; hardware protection, software
protection, and error protection.
6.9.1
Hardware Protection
Hardware protection refers to a state in which programming/erasing of flash memory is forcibly
disabled or aborted because of a transition to reset, subactive mode, subsleep mode, watch mode,
or standby mode. Flash memory control register 1 (FLMCR1), flash memory control register 2
(FLMCR2), and erase block register (EBR) are initialized. In a reset via the
RES
pin, the reset
state is not entered unless the
RES
pin is held low until oscillation stabilizes after powering on. In
the case of a reset during operation, hold the
RES
pin low for the
RES
pulse width specified in the
AC Characteristics section.
6.9.2
Software Protection
Software protection can be implemented against programming/erasing of all flash memory blocks
by clearing the SWE bit in FLMCR1. When software protection is in effect, setting the P or E bit
in FLMCR1 does not cause a transition to program mode or erase mode. By setting the erase
block register (EBR), erase protection can be set for individual blocks. When EBR is set to H'00,
erase protection is set for all blocks.
6.9.3
Error Protection
In error protection, an error is detected when CPU runaway occurs during flash memory
programming/erasing, or operation is not performed in accordance with the program/erase
algorithm, and the program/erase operation is aborted. Aborting the program/erase operation
prevents damage to the flash memory due to overprogramming or overerasing.
When the following errors are detected during programming/erasing of flash memory, the FLER
bit in FLMCR2 is set to 1, and the error protection state is entered.
•
When the flash memory of the relevant address area is read during programming/erasing
(including vector read and instruction fetch)
•
Immediately after exception handling excluding a reset during programming/erasing
•
When a SLEEP instruction is executed during programming/erasing
The FLMCR1, FLMCR2, and EBR settings are retained, however program mode or erase mode is
aborted at the point at which the error occurred. Program mode or erase mode cannot be re-entered
Содержание H8/38342
Страница 8: ...Rev 6 00 Aug 04 2006 page vi of xxxvi...
Страница 12: ...Rev 6 00 Aug 04 2006 page x of xxxvi...
Страница 38: ...Rev 6 00 Aug 04 2006 page xxxvi of xxxvi...
Страница 76: ...Section 1 Overview Rev 6 00 Aug 04 2006 page 38 of 680 REJ09B0145 0600...
Страница 240: ...Section 7 RAM Rev 6 00 Aug 04 2006 page 202 of 680 REJ09B0145 0600...
Страница 468: ...Section 12 A D Converter Rev 6 00 Aug 04 2006 page 430 of 680 REJ09B0145 0600...
Страница 580: ...Section 15 Electrical Characteristics Rev 6 00 Aug 04 2006 page 542 of 680 REJ09B0145 0600...