Section 5 Power-Down Modes
Rev. 6.00 Aug 04, 2006 page 151 of 680
REJ09B0145-0600
4. Time for direct transition from subactive mode to active (medium-speed) mode
A direct transition from subactive mode to active (medium-speed) mode is performed by
executing a SLEEP instruction in subactive mode while bit SSBY is set to 1 and bit LSON is
cleared to 0 in SYSCR1, bits MSON and DTON are both set to 1 in SYSCR2, and bit TMA3 is set
to 1 in TMA. The time from execution of the SLEEP instruction to the end of interrupt exception
handling (the direct transition time) is given by equation (4) below.
Direct transition time = { (Number of SLEEP instruction execution states) + (number of internal
processing states) }
×
(tsubcyc before transition) + { (wait time set in
STS2 to STS0) + (number of interrupt exception handling execution
states) }
×
(tcyc after transition)
........................ (4)
Example: Direct transition time = (2 + 1)
×
8tw + (8192 + 14)
×
16tosc = 24tw + 131296tosc
(when
φ
w/8 or
φ
8 is selected as the CPU operating clock, and wait time = 8192 states)
Notation:
tosc:
OSC clock cycle time
tw:
Watch clock cycle time
tcyc:
System clock (
φ
) cycle time
tsubcyc: Subclock (
φ
SUB
) cycle time
5.8.3
Notes on External Input Signal Changes before/after Direct Transition
1. Direct transition from active (high-speed) mode to subactive mode
Since the mode transition is performed via watch mode, see section 5.3.5, Notes on External
Input Signal Changes before/after Standby Mode.
2. Direct transition from active (medium-speed) mode to subactive mode
Since the mode transition is performed via watch mode, see section 5.3.5, Notes on External
Input Signal Changes before/after Standby Mode.
3. Direct transition from subactive mode to active (high-speed) mode
Since the mode transition is performed via watch mode, see section 5.3.5, Notes on External
Input Signal Changes before/after Standby Mode.
4. Direct transition from subactive mode to active (medium-speed) mode
Since the mode transition is performed via watch mode, see section 5.3.5, Notes on External
Input Signal Changes before/after Standby Mode.
Содержание H8/38342
Страница 8: ...Rev 6 00 Aug 04 2006 page vi of xxxvi...
Страница 12: ...Rev 6 00 Aug 04 2006 page x of xxxvi...
Страница 38: ...Rev 6 00 Aug 04 2006 page xxxvi of xxxvi...
Страница 76: ...Section 1 Overview Rev 6 00 Aug 04 2006 page 38 of 680 REJ09B0145 0600...
Страница 240: ...Section 7 RAM Rev 6 00 Aug 04 2006 page 202 of 680 REJ09B0145 0600...
Страница 468: ...Section 12 A D Converter Rev 6 00 Aug 04 2006 page 430 of 680 REJ09B0145 0600...
Страница 580: ...Section 15 Electrical Characteristics Rev 6 00 Aug 04 2006 page 542 of 680 REJ09B0145 0600...