Section 5 Power-Down Modes
Rev. 6.00 Aug 04, 2006 page 145 of 680
REJ09B0145-0600
5.5
Subsleep Mode
5.5.1
Transition to Subsleep Mode
The system goes from subactive mode to subsleep mode when a SLEEP instruction is executed
while the SSBY bit in SYSCR1 is cleared to 0, LSON bit in SYSCR1 is set to 1, and TMA3 bit in
TMA is set to 1. In subsleep mode, operation of on-chip peripheral modules other than the A/D
converter, PWM and WDT is halted. As long as a minimum required voltage is applied, the
contents of CPU registers, the on-chip RAM and some registers of the on-chip peripheral modules
are retained. I/O ports keep the same states as before the transition.
5.5.2
Clearing Subsleep Mode
Subsleep mode is cleared by an interrupt (timer A, timer C, timer F, timer G, asynchronous
counter, SCI1, SCI3-2, SCI3-1, IRQ
4
to IRQ
0
, WKP
7
to WKP
0
) or by a low input at the
RES
pin.
•
Clearing by interrupt
When an interrupt is requested, subsleep mode is cleared and interrupt exception handling
starts. Subsleep mode is not cleared if the I bit of CCR is set to 1 or the particular interrupt is
disabled in the interrupt enable register.
To synchronize the interrupt request signal with the subclock, up to 2/
φ
SUB
(s) delay may occur
after the interrupt request signal occurrence, before the interrupt exception handling start.
•
Clearing by
RES
input
Clearing by
RES
pin is the same as for standby mode; see 2. Clearing by
RES
pin in section
5.3.2, Clearing Standby Mode.
Содержание H8/38342
Страница 8: ...Rev 6 00 Aug 04 2006 page vi of xxxvi...
Страница 12: ...Rev 6 00 Aug 04 2006 page x of xxxvi...
Страница 38: ...Rev 6 00 Aug 04 2006 page xxxvi of xxxvi...
Страница 76: ...Section 1 Overview Rev 6 00 Aug 04 2006 page 38 of 680 REJ09B0145 0600...
Страница 240: ...Section 7 RAM Rev 6 00 Aug 04 2006 page 202 of 680 REJ09B0145 0600...
Страница 468: ...Section 12 A D Converter Rev 6 00 Aug 04 2006 page 430 of 680 REJ09B0145 0600...
Страница 580: ...Section 15 Electrical Characteristics Rev 6 00 Aug 04 2006 page 542 of 680 REJ09B0145 0600...