Rev. 6.00, 08/04, page 409 of 628
13.2.2
LCD Control Register (LCR)
Bit
Initial value
Read/Write
7
1
6
PSW
0
R/W
5
ACT
0
R/W
4
DISP
0
R/W
3
CKS3
0
R/W
0
CKS0
0
R/W
2
CKS2
0
R/W
1
CKS1
0
R/W
LCR is an 8-bit read/write register which performs LCD drive power supply on/off control and
display data control, and selects the frame frequency.
LCR is initialized to H'80 upon reset.
Bit 7—Reserved
Bit 7 is reserved; it is always read as 1 and cannot be modified.
Bit 6—LCD Drive Power Supply On/Off Control (PSW)
Bit 6 can be used to turn the LCD drive power supply off when LCD display is not required in a
power-down mode, or when an external power supply is used. When the ACT bit is cleared to 0,
or in standby mode, the LCD drive power supply is turned off regardless of the setting of this bit.
Bit 6
PSW
Description
0
LCD drive power supply off
(initial value)
1
LCD drive power supply on
Bit 5—Display Function Activate (ACT)
Bit 5 specifies whether or not the LCD controller/driver is used. Clearing this bit to 0 halts
operation of the LCD controller/driver. The LCD drive power supply is also turned off, regardless
of the setting of the PSW bit. However, register contents are retained.
Bit 5
ACT
Description
0
LCD controller/driver operation halted
(initial value)
1
LCD controller/driver operates
Содержание H8/38024 Series
Страница 18: ...Rev 6 00 08 04 page xviii of xxx...
Страница 30: ...Rev 6 00 08 04 page xxx of xxx...
Страница 130: ...Rev 6 00 08 04 page 100 of 628...
Страница 216: ...Rev 6 00 08 04 page 186 of 628...
Страница 416: ...Rev 6 00 08 04 page 386 of 628...
Страница 432: ...Rev 6 00 08 04 page 402 of 628...
Страница 468: ...Rev 6 00 08 04 page 438 of 628...
Страница 661: ...H8 38024 H8 38024S H8 38024F ZTAT H8 38124 Group Hardware Manual...