Rev. 6.00, 08/04, page 300 of 628
9.6.4
Watchdog Timer Operation States
Table 9.17(1) and table 9.17(2) summarize the watchdog timer operation states for the H8/38024,
H8/38024S, and H8/38024F-ZTAT Group, and for the H8/38124 Group, respectively.
Table 9.17(1)
Watchdog Timer Operation States
(H8/38024, H8/38024S, H8/38024F-ZTAT Group)
Operation
Mode
Reset
Active
Sleep
Watch
Subactive Subsleep Standby
Module
Standby
TCW
Reset
Functions
Functions
Halted
Functions/
Halted
*
Halted
Halted
Halted
TCSRW
Reset
Functions
Functions
Retained
Functions/
Halted
*
Retained
Retained
Retained
Note:
*
Functions when
φ
w/32 is selected as the input clock.
Table 9.17(2)
Watchdog Timer Operation States (H8/38124 Group)
Operation
Mode
Reset
Active
Sleep
Watch
Subactive Subsleep Standby
Module
Standby
TCW
Reset
Functions
Functions
Functions/
Halted
*
1
Functions/
Halted
*
1
Functions/
Halted
*
1
Functions/
Halted
*
2
Halted
TCSRW
Reset
Functions
Functions
Functions/
Retained
*
1
Functions/
Halted
*
1
Functions/
Retained
*
1
Functions/
Retained
*
2
Retained
TMW
Reset
Functions
Functions
Functions/
Retained
*
1
Functions/
Halted
*
1
Functions/
Retained
*
1
Functions/
Retained
*
2
Retained
Notes: 1. Operates when
φ
w/32 or the on-chip oscillator is selected as the internal clock.
2. Operates only when the on-chip oscillator is selected.
Содержание H8/38024 Series
Страница 18: ...Rev 6 00 08 04 page xviii of xxx...
Страница 30: ...Rev 6 00 08 04 page xxx of xxx...
Страница 130: ...Rev 6 00 08 04 page 100 of 628...
Страница 216: ...Rev 6 00 08 04 page 186 of 628...
Страница 416: ...Rev 6 00 08 04 page 386 of 628...
Страница 432: ...Rev 6 00 08 04 page 402 of 628...
Страница 468: ...Rev 6 00 08 04 page 438 of 628...
Страница 661: ...H8 38024 H8 38024S H8 38024F ZTAT H8 38124 Group Hardware Manual...