Rev. 6.00, 08/04, page 310 of 628
Bit 6
OVL
Description
0
ECL has not overflowed
(initial value)
Clearing condition:
After reading OVL = 1, cleared by writing 0 to OVL
1
ECL has overflowed
Setting condition:
Set when ECL overflows from H'FF to H'00
Bit 5—Reserved
Bit 5 is a readable/writable reserved bit. It is initialized to 0 by a reset.
Bit 4—Channel Select (CH2)
Bit 4 selects whether ECH and ECL are used as a single-channel 16-bit event counter or as two
independent 8-bit event counter channels. When CH2 is cleared to 0, ECH and ECL function as a
16-bit event counter which is incremented each time an event clock is input to the AEVL pin. In
this case, the overflow signal from ECL is selected as the ECH input clock. When CH2 is set to 1,
ECH and ECL function as independent 8-bit event counters which are incremented each time an
event clock is input to the AEVH or AEVL pin, respectively.
Bit 4
CH2
Description
0
ECH and ECL are used together as a single-channel 16-bit event counter
(initial value)
1
ECH and ECL are used as two independent 8-bit event counter channels
Bit 3—Count-up Enable H (CUEH)
Bit 3 enables event clock input to ECH. When 1 is written to this bit, event clock input is enabled
and increments the counter. When 0 is written to this bit, event clock input is disabled and the
ECH value is held. The AEVH pin or the ECL overflow signal can be selected as the event clock
source by bit CH2.
Bit 3
CUEH
Description
0
ECH event clock input is disabled
(initial value)
ECH value is held
1
ECH event clock input is enabled
Содержание H8/38024 Series
Страница 18: ...Rev 6 00 08 04 page xviii of xxx...
Страница 30: ...Rev 6 00 08 04 page xxx of xxx...
Страница 130: ...Rev 6 00 08 04 page 100 of 628...
Страница 216: ...Rev 6 00 08 04 page 186 of 628...
Страница 416: ...Rev 6 00 08 04 page 386 of 628...
Страница 432: ...Rev 6 00 08 04 page 402 of 628...
Страница 468: ...Rev 6 00 08 04 page 438 of 628...
Страница 661: ...H8 38024 H8 38024S H8 38024F ZTAT H8 38124 Group Hardware Manual...