Rev. 6.00, 08/04, page 120 of 628
10. On the H8/38124 Group, operates when
φ
W
/32 is selected as the internal clock or the on-chip oscillator is selected;
otherwise stops and stands by. On the H8/38024, H8/38024S, and H8/38024F-ZTAT Group, stops and stands by.
11. On the H8/38124 Group, operates only when the on-chip oscillator is selected; otherwise stops and stands by. On
the H8/38024, H8/38024S, and H8/38024F-ZTAT Group, stops and stands by.
5.1.1
System Control Registers
The operation mode is selected using the system control registers described in table 5.3.
Table 5.3
System Control Registers
Name
Abbreviation
R/W
Initial Value
Address
System control register 1
SYSCR1
R/W
H'07
H'FFF0
System control register 2
SYSCR2
R/W
H'F0
H'FFF1
System Control Register 1 (SYSCR1)
Bit
Initial value
Read/Write
7
SSBY
0
R/W
6
STS2
0
R/W
5
STS1
0
R/W
4
STS0
0
R/W
3
LSON
0
R/W
0
MA0
1
R/W
2
1
1
MA1
1
R/W
SYSCR1 is an 8-bit read/write register for control of the power-down modes.
Upon reset, SYSCR1 is initialized to H'07.
Bit 7—Software Standby (SSBY)
This bit designates transition to standby mode or watch mode.
Bit 7
SSBY
Description
0
•
When a SLEEP instruction is executed in active mode,
(initial value)
a transition is made to sleep mode
•
When a SLEEP instruction is executed in subactive mode, a transition is made to
subsleep mode
1
•
When a SLEEP instruction is executed in active mode, a transition is made to
standby mode or watch mode
•
When a SLEEP instruction is executed in subactive mode, a transition is made to
watch mode
Содержание H8/38024 Series
Страница 18: ...Rev 6 00 08 04 page xviii of xxx...
Страница 30: ...Rev 6 00 08 04 page xxx of xxx...
Страница 130: ...Rev 6 00 08 04 page 100 of 628...
Страница 216: ...Rev 6 00 08 04 page 186 of 628...
Страница 416: ...Rev 6 00 08 04 page 386 of 628...
Страница 432: ...Rev 6 00 08 04 page 402 of 628...
Страница 468: ...Rev 6 00 08 04 page 438 of 628...
Страница 661: ...H8 38024 H8 38024S H8 38024F ZTAT H8 38124 Group Hardware Manual...