Rev. 6.00, 08/04, page 333 of 628
Bit 6—Receive Data Register Full (RDRF)
Bit 6 indicates that received data is stored in RDR.
Bit 6
RDRF
Description
0
There is no receive data in RDR
(initial value)
Clearing conditions:
After reading RDRF = 1, cleared by writing 0 to RDRF
When RDR data is read by an instruction
1
There is receive data in RDR
Setting condition:
When reception ends normally and receive data is transferred from RSR to RDR
Note:
If an error is detected in the receive data, or if the RE bit in SCR3 has been cleared to 0,
RDR and bit RDRF are not affected and retain their previous state.
Note that if data reception is completed while bit RDRF is still set to 1, an overrun error
(OER) will result and the receive data will be lost.
Bit 5—Overrun Error (OER)
Bit 5 indicates that an overrun error has occurred during reception.
Bit 5
OER
Description
0
Reception in progress or completed
*
1
(initial value)
Clearing condition:
After reading OER = 1, cleared by writing 0 to OER
1
An overrun error has occurred during reception
*
2
Setting condition:
When reception is completed with RDRF set to 1
Notes: 1. When bit RE in SCR3 is cleared to 0, bit OER is not affected and retains its previous
state.
2. RDR retains the receive data it held before the overrun error occurred, and data
received after the error is lost. Reception cannot be continued with bit OER set to 1,
and in synchronous mode, transmission cannot be continued either.
Содержание H8/38024 Series
Страница 18: ...Rev 6 00 08 04 page xviii of xxx...
Страница 30: ...Rev 6 00 08 04 page xxx of xxx...
Страница 130: ...Rev 6 00 08 04 page 100 of 628...
Страница 216: ...Rev 6 00 08 04 page 186 of 628...
Страница 416: ...Rev 6 00 08 04 page 386 of 628...
Страница 432: ...Rev 6 00 08 04 page 402 of 628...
Страница 468: ...Rev 6 00 08 04 page 438 of 628...
Страница 661: ...H8 38024 H8 38024S H8 38024F ZTAT H8 38124 Group Hardware Manual...