wrench. Screw the selected REMS universal diamond core drilling crown/REMS
universal diamond core drilling crown LS onto the drive spindle (11) of the drive
unit and lightly hand-tighten. There is no need to tighten it with a wrench.
Use dust extraction and a suitable safety vacuum cleaner/dust extractor, e.g.
REMS Pull M (see 2.4.2.). The diamond core drilling crown could be damaged
by overheating if the dust produced by dry drilling is not sucked off. There is
also a risk of injury when the drilling dust compressed in the gap blocks the
diamond core drilling crown. If you have to work without dust extraction in fi ne-
pored material, the diamond core drilling crown should be pulled back as often
as possible and pushed forward again with a slight swing so that the drilling
dust is pushed out of the drilling gap. Suitable safety equipment, e.g. respirator,
disposable overalls, must be used. Observe the national regulations.
Make sure that the suction hose of the safety vacuum cleaner/dust extractor does
not kink and impair the dust extraction. Also make sure that no fragments of stone
or other objects jam in the diamond core drilling crown, the suction rotor ((46)
accessory art. no. 180160) and/or the suction hose. Empty the dust bag of the
safety vacuum cleaner/dust extractor early and clean/renew the fi lter regularly.
Observe the operating instructions of the safety vacuum cleaner/dust extractor.
Switch on the drive unit with safety inching switch (21). To do this, push forward
the switch-on lock and press the safety inching switch at the same time. Push
the switch-on lock forward again to lock the safety inching switch (Picus S1
and Picus S3). In Picus SR the knob next to the safety inching switch (21) must
be pressed to lock the switch (21) when pressed. Hold the diamond core drilling
crown by the insulated grip surfaces, move forward slowly with the feed lever
(4) and start tapping carefully. Once the diamond core drilling crown has engaged
all-round, the feed rate can be increased. If the drive unit is stopped due to
excessive feed pressure, or becomes blocked as a result of resistance in the
drilling gap, the multi-function elec tronic system reduces the motor current – and
thus the turning speed of the drive unit – to a minimum. The drive unit does not
shut down how ever. As the feed pressure is reduced, the turning speed of the
drive unit is increased once more. This procedure, even if it is repea ted several
times in succession, prevents damage to the drive unit. If the motor remains
stopped despite the reduction in feed pressure, the drive unit must be shut
down and the diamond core drilling crown freed manually (see 5.).
WARNING
WARNING
Pull out the mains plug!
NOTICE
NOTICE
Always wet drilling with REMS universal diamond core drilling crowns
and REMS universal diamond core drilling crowns LS for steel-reinforced
concrete!
Always dry drilling with REMS dry diamond core drilling crowns LS with
core drilling machines with micro-pulse technology. Suck off the resulting
drilling dust with a suitable safety vacuum cleaner/dust extractor! Observe
the national regulations.
REMS Picus S2/3,5
Loosen the two screws (52) on the fl ange of the REMS Titan, insert REMS
Picus S2/3,5 in the guide (53). Hold the drive machine and tighten the screws
(52). Tighten the locking nut. Screw the selected diamond core drill crown to
the drive spindle (11) of the drive machine and tighten by hand with a slight
swing. There is no need to use an open-ended wrench for tightening. Switch
on the drive unit with the rocker switch (21a). Hold the diamond core drilling
crown by the insulated grip surfaces, move forward slowly with the feed lever
(4) and start tapping carefully. Once the diamond core drilling crown has engaged
all-round, the feed rate can be increased. If the drive unit is stopped due to
excessive feed pressure, or becomes blocked as a result of resistance in the
drilling gap, the multi-function elec tronic system reduces the motor current – and
thus the turning speed of the drive unit – to a minimum. The drive unit does not
shut down how ever. As the feed pressure is reduced, the turning speed of the
drive unit is increased once more. This procedure, even if it is repea ted several
times in succession, prevents damage to the drive unit. If the motor remains
stopped despite the reduction in feed pressure, the drive unit must be shut down
and the diamond core drilling crown freed manually (see 5.).
WARNING
WARNING
Pull out the mains plug!
NOTICE
NOTICE
Always wet drilling with REMS universal diamond core drilling crowns
and REMS universal diamond core drilling crowns LS for steel-reinforced
concrete!
Always dry drilling with REMS dry diamond core drilling crowns LS with
core drilling machines with micro-pulse technology. Suck off the resulting
drilling dust with a suitable safety vacuum cleaner/dust extractor! Observe
the national regulations.
REMS Picus DP
NOTICE
NOTICE
For dry drilling in concrete/steel-reinforced concrete with REMS Picus DP and
the REMS dry diamond core drilling crowns LS, it is necessary to switch on the
micro-pulse technology and use a suitable safety vacuum cleaner/dust extractor
of dust class M, e.g. REMS Pull M, for dust extraction. For drilling in masonry
and other materials, the micro-pulse technology can be switched off and a
suitable safety vacuum cleaner/dust extractor, e.g. REMS Pull M, must be used.
Observe the national regulations.
Fix the drill stand in one of the ways described in 3.3. N.B.: The vacuum
fastening is not approved for drilling with REMS Picus DP. Insert the drill collar
(13) of the drive unit into the mounting in the clamping angle (10) and tighten the
fi llister head screw(s) (8) with a size 6 Allen key. Screw the selected diamond
core drilling crown onto the drive spindle (11) of the drive unit and lightly hand-
tighten. There is no need to tighten it with an open-ended wrench. Switch on the
micro-pulse technology. To do this, turn the micro-pulse technology adjusting
ring (Fig. 10 (69)) to the detent position so that the red markings are in line.
When drilling in masonry and other materials, the micro-pulse technology can
be switched off by turning the micro-pulse technology adjusting ring (69) to the
detent position so that the red markings are not in line.
Connect a suitable safety vacuum cleaner/dust extractor, e.g. REMS Pull M, to
REMS Picus DP (see 2.4.2.). If the dust produced by dry drilling is not removed,
the diamond core drilling crown may overheat and suffer damage. There is also
a risk of injury when the drilling dust compressed in the gap blocks the diamond
core drilling crown Observe the national regulations.
Make sure that the suction hose of the safety vacuum cleaner/dust extractor
does not kink and impair the dust extraction. Also make sure that no loosened
lumps of rock or other objects jam in the diamond core drilling crown, the drive
unit’s suction rotor and/or the suction hose. Empty the dust bag of the safety
vacuum cleaner/dust extractor early and clean/renew the fi lter regularly. Observe
the operating instructions of the safety vacuum cleaner/dust extractor.
Switch on the drive unit with safety inching switch (21). To do this, push forward
the switch-on lock and press the safety inching switch at the same time. Push
the switch-on lock forward again to lock the safety inching switch. Hold the
diamond core drilling crown by the insulated grip surfaces, move forward slowly
with the feed lever (4) and start tapping carefully. It may be an advantage to
switch off the micro-pulse technology for tapping. Once the diamond core drilling
crown has engaged all-round, the feed rate can be increased If the drive unit
is stopped due to excessive thrust pressure or becomes blocked as a result
of resistance in the drilling gap, the multi-function electronic system reduces
the motor current and thus the turning speed of the drive unit to a minimum.
However, the drive unit does not switch off. If the thrust pressure is reduced, the
turning speed of the drive unit increases again. This process does not damage
the drive unit even if it is repeated several times. If the motor remains stopped
despite the reduction in thrust pressure, the drive unit must be shut down and
the diamond core drilling crown freed manually (see 5.).
WARNING
WARNING
Pull out the mains plug!
NOTICE
NOTICE
Always wet drilling with REMS universal diamond core drilling crowns
and REMS universal diamond core drilling crowns LS for steel-reinforced
concrete!
Always dry drilling with REMS dry diamond core drilling crowns LS with
core drilling machines with micro-pulse technology. Suck off the resulting
drilling dust with a suitable safety vacuum cleaner/dust extractor! Observe
the national regulations.
3.5 Wet-boring with drill upright
WARNING
WARNING
REMS Picus DP is delivered without a PRCD fault current circuit breaker and
is suitable for dry drilling only. Wet drilling with, as well as connection of a water
hose to the REMS Picus DP is not permitted. There is a danger of electric
shock.
REMS Picus S1, REMS Picus S3 and REMS Picus SR
Secure the drill upright using one of the methods described in 3.3. Insert the
drill collar (13) of the drive unit into the mounting in the clamping angle (10),
and tighten the fi llister head screw(s) (8) with an SW 6 hexa gon socket head
wrench. Screw the selected REMS universal diamond core drilling crown/REMS
universal diamond core drilling crown LS onto the drive spindle (11) of the drive
unit and lightly hand-tighten. There is no need to tighten it with a wrench.
Connect the water supply (see 2.5.). Switch on the drive unit with safety inching
switch (21). To do this, push forward the switch-on lock and press the safety
inching switch at the same time. Push the switch-on lock forward again to lock
the safety inching switch (Picus S1 and Picus S3). In Picus SR the knob next
to the safety inching switch (21) must be pressed to lock the switch (21) when
pressed. Hold the diamond core drilling crown by the insulated grip surfaces,
move forward slowly with the feed lever (4) and start tapping carefully with a
low water supply. Once the diamond core drilling crown has engaged all-round,
the feed rate can be increased. Adjust the water pressure to a point where there
is a moderate, but constant, fl ow for water from the bore hole. Insuffi cient water
pressure (where the waste material fl ows out of the bore hole as thick sludge
rather than liquid) is as bad for the working effi ciency and service life of the
diamond core drilling crown as is excessive water pressure, which causes
completely clear water to fl ow out. Suck up the drilling water preferably with a
suitable dry and wet vacuum cleaner, e.g. REMS Pull L or REMS Pull M.
WARNING
WARNING
Ensure that no water is allowed to get into the drive unit motor during
operation. DANGER OF FATAL ACCIDENT!
If the drive unit is stopped due to excessive feed pressure, or becomes blocked
as a result of resistance in the drilling gap, the multi-function elec tronic system
reduces the motor current – and thus the turning speed of the drive unit – to a
eng eng
27
Содержание Picus DP
Страница 6: ...Fig 13 23 24 25 26 27 28 50 54 55 22 62 63 64 64 65 66 67 56 6...
Страница 302: ...302...
Страница 303: ...303...